Fig. 3.3 - 1 Electrical and pneumatic connection points on the placement system
(1) Compressed air unit
(2) Connection for compressed air line
(3) Main power filter Z1
(4) Hole for power cable
(5) Service socket
(6) Compressed air connection for component trolleys
(7) Power supply connection for component trolley
(8) Communications connection for component trolley
(9) LAN connection in the control unit
(10) Main switch
(11) Control cable connection for matrix tray changer
User Manual SIPLACE S-27 HM 3 Technical data
Software version SR.503.xx 07/2003 US Edition 3.3 Electrical and pneumatic connection points
79
WARNING
The placement system is supplied with 3 x 400 VAC or 3 x 208 VAC US version) ± 5%, 50/60 Hz
main power voltage. This means that some parts of the system carry potentially lethal voltages -
even when switched off at the main power switch. Death, serious injury or considerable damage
may result if this automatic placement system is handled incorrectly. 3
WARNING
Never disconnect compressed air lines while they are pressurized. Risk of injury. 3
3 Technical data User Manual SIPLACE S-27 HM
3.4 Technical data – ratings Software version SR.503.xx07/2003 US Edition
80
3.4 Technical data – ratings
3.4.1 Technical data – electrical ratings
3
3.4.2 Technical data – compressed air supply
3
3.4.3 Technical data – compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1)
3.4.4 Technical data – noise emissions
3
3.4.5 Technical data – permissible ambient factors
3
Supply voltage 3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 208 VAC ± 5 %; 50/60 Hz (USA)
3 x 200 VAC ± 5 %; 50/60 Hz (Japan, option)
Fuses 3 x 16 A (3 x 400 VAC, 3 x 208 VAC, 3 x 200 VAC)
Total connected load 5 kVA
Total power 2 kW
Power failure Max. 20 msec
Compressed air pressure Min. 0.55 MPa (5.5 bar) to 0.8 MPa (8 bar), ½"-connection
Compressed air consumption 400 Nl/min.
Operating pressure Set to 0.52 MPa (5.2 bar)
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint +3°
Max. noise emission 74dB(A)
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 to 80%
(but no higher than 45% on average in order to prevent
any possibility of condensation on the machine).