AltaPail II Bulk Melters Product Manual.pdf - 第122页
Advanced Software M elter Configuration 7 -36 Part 1121836_03 E 1 1/2014 Nordson Corporation Reverting back to a Previous Version As part of the upgrade process, the current *.da t file is a utomatically copied into the …

Advanced Software Melter Configuration
7-35
Part 1121836_03
E 11/2014 Nordson Corporation
Locating the Customer and Internal SD Cards
The LCD Module includes two SD Card slots:
S
Customer SD Card - Contains a \backup folder for when you want to
revert back to a previous working version of the software, as well as the
EventLog.csv and the diagnostic.nor files.
S
Internal SD Card - Contains system files and a \Recipes folder where all
recipes are stored. Refer to Distributing Recipes with other AltaPail II
Melters for more information.
NOTE: You must switch the melter off, and disconnect the electrical power to
the melter at the local power source before accessing either SD Card.
Customer SD Card
Internal SD Card
Figure 7-1 Location of the Customer and Internal SD Cards.

Advanced Software Melter Configuration
7-36
Part 1121836_03
E 11/2014 Nordson Corporation
Reverting back to a Previous Version
As part of the upgrade process, the current *.dat file is automatically copied
into the \backup directory of the Customer SD Card.
Before attempting to revert to a previous version, make sure of the following:
S
You have a computer with an SD Card device with Read/Write
capabilities.
Starting
Entering Flash
Loader Version: 01.05
Found Upgrade File
Updating Firmware
Percent Complete: 40
Figure 7-2 The upgrade process.
1. Switch the melter off, and disconnect the electrical power to the melter at
the local power source. Open the door to access the CPU board.
2. Locate and remove the Customer SD card. Refer to Figure 7-1.
3. Using your PC, do the following:
S
Navigate to the \backup directory and copy the *.dat file you want.
S
Navigate to the root of the SD Card and paste the *.dat file.
4. Replace the Customer SD Card, close the access door, reconnect the
local power source, and switch the melter On. Refer to Figure 7-2.
5. The system automatically detects a new *.dat file and does the following:
S
A copy of the current *.dat file is copied into the \backup directory on
the SD Card.
S
The CPU board is upgraded first, followed by the Motor Control
board.
S
The entire upgrade process should take approximately 10 minutes.
When done, the software automatically reboots the melter. The
upgrade is complete.

Advanced Software Melter Configuration
7-37
Part 1121836_03
E 11/2014 Nordson Corporation
Managing Recipes
Use recipes to save production settings, such as zones and pump settings,
as well as other melter settings including scheduled events, and security
settings, to a file that you can use, modify, delete and share or copy with
other AltaPail II melters.
NOTE:
S
Recipes are stored in the \Recipes folder located on the Internal SD
Card. Refer to Figure 7-1 to locate the Internal SD card.
S
Refer to table 7-1 for more information about what is saved to a
recipe.
S
The melter retains the settings of the previously loaded recipe, even if
you delete or decide not to make use of a recipe.
Accessing the Recipes Screen
You can access the Recipes screen by doing one of the following:
S
From the Operator Display, touch Recipes.
-
Refer to Figure 7-3.
S
From the Master Controls | System | Administration, then touch
Recipes.
-
Refer to Figure 7-4.
Recipes:
Nothing Loaded
Touch here to create, load or modify and save recipes.
Figure 7-3 Accessing Recipes from the Operator Display