Basic Software Melter Configuration 6 -12 Part 1121836_03 E 1 1/2014 Nordson Corporation Basic Pump C onfigurat ion You can do the fol lowing tasks: S Change Operation Modes S Switch the pump On/Off S Adjust the speed (R…

100%1 / 230
Basic Software Melter Configuration
6-11
Part 1121836_03
E 11/2014 Nordson Corporation
Configuring the Pump
By default, you should be able to Enable/Disable the pump, change its
Operation mode (Manual or Gear-to-Line) and adjust its speed (RPM).
Use the Advanced pump settings to Calibrate the pump, enable/disable the
Auto Pump option, define Low Adhesive Timeout and hand applicator/pump
settings. Refer to the next chapter for more information.
Requirements for Running the Pump
The following lists the system requirements before you can run the pump:
S
The melter status must indicate Ready/OK.
S
The pump must be On.
S
In addition to the Platen, at least one external zone must be enabled.
S
The Master Heater Control must indicate On.
S
The Master Pump Control must indicate On.
NOTES:
S
The Master Pump and Heater Controls automatically switch Off,
when the melter is in a Fault condition.
S
You must wait until the melter status indicates Ready\OK before you
can manually or remotely switch On the Pump.
S
Use the Auto Pump option to automatically switch On the Pump
once the melter status indicates Ready\OK.
S
The state of a pump is independent of the overall status of the melter.
S
Make sure to save your changes to a recipe. Refer to Managing
Recipes for more information.
S
You can make use of standard or hand applicators in Manual or
Gear-to-Line pump operation modes.
S
If you connect a standard (automatic) applicator to one external zone
and a handgun to a different external zone, regardless of which you
connect first, the pump will operate in hand applicator mode. The
Home screen also displays both zones with a handgun icon,
Basic Software Melter Configuration
6-12
Part 1121836_03
E 11/2014 Nordson Corporation
Basic Pump Configuration
You can do the following tasks:
S
Change Operation Modes
S
Switch the pump On/Off
S
Adjust the speed (RPM) of the pump
The following sections detail each task in greater detail.
NOTE: Refer to Advanced Pump Settings in the next chapter for more
information.
Basic Software Melter Configuration
6-13
Part 1121836_03
E 11/2014 Nordson Corporation
Changing Pump Operation Modes
Notes:
S
You can make use of standard or hand applicators in Manual or
Gear-to-Line pump operation modes.
S
If you connect a standard (automatic) applicator to one external zone
and a hand applicator to a different external zone, regardless of which
you connect first, the pump will operate in hand applicator mode. The
Home screen also displays both zones with a hand applicator icon.
Setting Default Option
Operation Mode Manual
S
Manual - Delivers adhesive at a constant speed you
manually enter. Use Manual Mode to purge the melter.
S
Gear-to-Line - Delivers adhesive at a rate proportional
to the line speed.
Pump
Done
Adjust Speed
Pump Control
85 RPM
Advanced
Pump Operation Mode
Done
Cancel
Manual
Gear-to-Line
1. Access the Home screen, touch
Pump
GTL
45 RPM
then the Advanced button
2. Touch Change Operation Mode and select which pump mode you want
to use.
Operation Mode Description
Manual Pump runs at a constant Speed.
Gear-to-Line Pump runs runs at a variable speed based on line
speed signal.
3. Touch Done.