Maintenanc e 8-7 Part 1121836_03 E 11/2014 Nordson Corporation Fan and A ir Filter Depending on dust accumulation, the air filters in the fan and for the air outlet must be cleaned (knocked out) or replac ed. Refer to se…

100%1 / 230
Maintenance
8-6
Part 1121836_03
E 11/2014 Nordson Corporation
Purging with Cleaning Agent
Place a container of cleaning agent in the bulk melter to purge. Then feed the
cleaning agent until it comes out free of material residue.
CAUTION: Use only a cleaning agent recommended by the hot melt
material manufacturer. Observe the Material Safety Data Sheet for the
cleaning agent.
Before starting production again, flush out residue of the cleaning agent
using the new material.
NOTE: Properly dispose of cleaning agent according to local regulations.
Cleaning Melting Plate
The melting plate is standardly release-coated. This makes it easy to clean.
Cooled material can usually be pulled off of the melting plate; if necessary,
first heat to approx. 60 ° C / 140 ° F.
CAUTION: Do not use hard or metallic tools to clean. Do not use wire
brushes! This could damage the release coating. Use only soft aids
(wooden or PTFE spatula or soft brush).
Maintenance
8-7
Part 1121836_03
E 11/2014 Nordson Corporation
Fan and Air Filter
Depending on dust accumulation, the air filters in the fan and for the air outlet
must be cleaned (knocked out) or replaced.
Refer to separate document Parts for filter order numbers.
Figure 8-1
1 Fan 2 Air filter, air outlet
Maintenance
8-8
Part 1121836_03
E 11/2014 Nordson Corporation
Motor / Gear Box
Change lubricant
Observe when changing lubricant:
S
Drain lubricant when warm
S
Use only the stated lubricant or one that has proven to be equivalent.
Using any other lubricant can result in premature wear and/or damage to
the gear box
S
Properly dispose of the old lubricant according to local regulations.
Remove gear box from the motor to change lubricant. Wash out casing with
suitable cleaning agent and remove lubricant residue.
Lubricant Changing Interval
When lubricant temperature is below 100° C / 212° F:
Every 15000 hours of operation or at least every 2 to 3 years.
Capacity
The lubricant quantity is indicated on the ID plate.
NOTE: Never mix different types of lubricants.
Lubricant Selection
Lubricant manufacturer Mineral oil CLP 220
AGIP Blasia 220
ARAL Degol BMB 220 or Degol BG 220
BP Energol GR-XP 220
DEA Falcon CLP 220
ESSO Spartan EP 220 or GP 90
KLÜBER Klüberoil GEM 1-220
OPTIMOL Optigear 220
SHELL Omala Oil 220
TEXACO Geartex EP-A SAE 85 W-90