Troubleshooting 9-4 Part 1121836_03 E 11/2014 Nordson Corporation System Faults Table 9- 3 System F aults Screen Message Affect on Melter Cause Co rrective Action(s) Brownout Master pump and heaters are switch ed off. Me…

100%1 / 230
Troubleshooting
9-3
Part 1121836_03
E 11/2014 Nordson Corporation
System Alerts
Table 9-2 System Alerts
Screen Message Affect on Melter Cause Corrective Action(s)
Failed motor board
The
melter
continues to work,
but some functions
may not be
available. Melter
requires servicing.
Communication failure between
CPU and the motor board
Replace motor board
NVRAM test failure
Internal RAM failure Replace CPU
Troubleshooting
9-4
Part 1121836_03
E 11/2014 Nordson Corporation
System Faults
Table 9-3 System Faults
Screen Message Affect on Melter Cause Corrective Action(s)
Brownout
Master
pump
and
heaters are switched
off. Melter stops
functioning
Plant power dipped and came
back up
Typically nothing to address,
unless the system does not
operate properly, or various
messages appear. Cold
Stop/Start the melter
.
Analog-to-Digital
Failure
RTD analog-to-digital converter
failed
Replace main board or CPU
Analog-to-Digital
Failure Calibration
Failed hose or applicator
RTD analog-to-digital converter
could not be calibrated
(grounded RTD in system)
Replace hose or applicator.
Note: Set setpoint to zero to
avoid fault.
Replace main board or ribbon
cable, or CPU
Expansion Board
Connection Failure
Communication failure between
expansion board and main board
Check the ribbon cable
connections between the
expansion board and the main
board.
Expansion Board
Failure
Replace the expansion board.
User Interface Failed
to Load
Reload SD card info
Replace SD card
Replace CPU
Main Board Failure
Replace the main board
RAM Failure
Replace CPU
Motor
Communication
Failure
Refer to Motor Drive Faults later
in this section for more
information
Motor Thermostat
Failure
Motor thermostat is open Replace thermostat
Platen Thermostat
Failure
Platen thermostat is open Replace thermostat, J7 harness,
or main board
Runaway fault on
[ZoneName]
Temperature continues to rise
beyond set point.
Replace Hose/applicator cordset
Replace main board
Troubleshooting
9-5
Part 1121836_03
E 11/2014 Nordson Corporation
Motor Drive Faults
The display on the motor drive located inside the electrical enclosure alerts
the operator to abnormal motor drive/motor operation. Motor drive faults
cause the pump to stop. Refer to Table 9-4 for the motor drive fault codes.
To clear a motor drive fault, correct the problem that caused the fault and
then remove power from the motor drive by turning the heaters off and wait
until the motor drive display is completely blank.
Figure 9-1 Motor drive power LED and display
1. Motor drive power LED (steady=OK,
flashing=fault, off=no power)
2. Display