AltaPail II Bulk Melters Product Manual.pdf - 第52页
About the Touch Screen Display and U ser Interface 5 -1 Part 1121836_03 E 1 1/2014 Nordson Corporation Section 5 About the Touch Screen D isplay and User Inte rface WARNING! Allow only qual ified personnel to p erform th…

Hardware Operation
4-10
Part 1121836_03
E 11/2014 Nordson Corporation
Output Quantity SN0371 (Formerly PR12m2)
The output quantity is a factor of the pump used.
0
50
100
150
200
250
300
350
400
0 10 20 30 40 50 60 70 80 90 100
Speed
[min
-1
]
Output
[ccm]
*
)
5 bar
*
*
30 bar
*
*
*)
Depending on application, consider influence of
S
type/density of hot melt material
S
operating temperature
S
hose length (longer hose ᇅ lower output rate)
S
input pressure (increasing input pressure ᇅ increasing output rate)
Test setup
Test material: HS5100 Fuller
Density: 0.809 g/ccm @ 140 ° C
Viscosity: approx. 4200 m Pas @ 140 ° C
Temperature: 140 ° C (284 ° F)
Hydrostatic input pressure
**
(
Application pressure (measured at melter hose port)
Range of recommended speed

About the Touch Screen Display and User Interface
5-1
Part 1121836_03
E 11/2014 Nordson Corporation
Section 5
About the Touch Screen Display and
User Interface
WARNING! Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.

About the Touch Screen Display and User Interface
5-2
Part 1121836_03
E 11/2014 Nordson Corporation
Overview
The touch screen display replaces the membrane control panel used on
previous Nordson melters. With a touch of your finger on the display screen,
you can navigate the graphical user interface to setup, operate and maintain
this melter.
The melter is shipped from the factory with most software settings
pre-configured and ready to use. However, there are some settings that you
must configure and fine-tune to best fit your manufacturing process.