AltaPail II Bulk Melters Product Manual.pdf - 第226页

Technical Dat a 12-4 Part 1121836_03 E 11/2014 Nordson Corporation Rated Current / Operatin g Voltage Pairs of Receptacles Hose/Applica tor 1 Hose/Applicator 2 2 Operating voltage AltaPail 400 V 3 Ph Y 17 A 240 V 3 Ph  …

100%1 / 230
Technical Data
12-3
Part 1121836_03
E 11/2014 Nordson Corporation
Temperatures
CAUTION: The temperature setting is determined by the processing
temperature prescribed by the material supplier. You cannot exceed the
maximum operating temperature for the system and heated components.
For Melters:
7407039, 7407040, 7407041, 7407042, 7407668 and 7407669
Item Software Limit System Limit
Min. operating temperature (set point) 40 ° C 100 ° F
Max. operating temperature 176 ° C 350 ° F
Over temperature shutdown by thermostat 210 ° C 410 ° F
For Melters:
7407664, 7407665, 7407666, 7407667, 7407670 and 7407671
Item Software Limit System Limit
Min. operating temperature (set point) 40 ° C 100 ° F
Max. operating temperature 232 ° C 450 ° F
Over temperature shutdown by thermostat 260 ° C 500 ° F
Temperature sensor type Ni 120
Electrical Data
WARNING! The unit is designed for only one operating voltage. Operate only
at the operating voltage shown on the ID plate.
Available Operating
Voltages
240 VAC 3-phase without neutral (Delta)
400/230 VAC 3-phase with neutral (Star - WYE)
480 VAC 3-phase without neutral (Delta)
NITE: 400/230 VAC is for electrical service with neutral (WYE) where the
400 VAC us a line-to-line voltage and 230 VAC is a line-to-neutral voltage.
Permitted Deviation from
Operating Voltage
¦ 10%
Operating Voltage
Frequency
50/60 Hz
Maximum Power output per
Heating Channel
NOTE: Each receptacle supplies two heating channels 1000 W but also
maximum 1200 W per receptacle Hose/Applicator, and for receptacle
pairs - maximum 2000 W total per pair.
NOTE: Pairs of receptacles:
* Hose/Gun 1
* Hose/Gun 2
Technical Data
12-4
Part 1121836_03
E 11/2014 Nordson Corporation
Rated Current / Operating Voltage
Pairs of Receptacles Hose/Applicator 1 Hose/Applicator 2
2
Operating voltage AltaPail
400 V
3 Ph Y
17 A
240 V
3 Ph
27 A
480 V
3 Ph
14 A
Technical Data
12-5
Part 1121836_03
E 11/2014 Nordson Corporation
Dimensions and Weights
Weight
Transformer and hood kit: 50 Kg (110 Lbs)
Transformer and hood kit and melter: 385 Kg (847 Lbs)
Dimensions
in
mm
Figure 12-1 Dimensions in brackets: Space required for installation