Viewing the Event Log
Use the event log to help troubleshoot issues with the melter.
NOTE: You can also view the vent log by touching the middle melter status
middle button located at the bottom of the Home
screen.
You can do the following:
S
Filter specific events or review all events for viewing purposes only
within the Display/Save Diagnostics screen.
S
View up to 200 of the most recent events.
S
Touch Save File to write ALL events, regardless of which filter you
selected to the Customer SD card. Refer to Figure 7-1.
Next
Cancel
Display/Save Diagnostics
Complete Event Log
Home
Faults Only
Warnings Only
Parameters / Set Point
Changes
Back
Done
Display/Save Diagnostics
Save File
Home
05/04/12
Source: System
Zone/Parameter: 0
11:52:20 Event Ready enter
0
Status:OK
Zone/Sub-code:
05/04/12
Source: System
Zone/Parameter: 0
11:52:50 Event Ready enter
0
Status:OK
Zone/Sub-code:
05/04/12
Source: HMI
Zone/Parameter: 17
11:40:03 Event Zone control off
0
Status:OK
Zone/Sub-code:
05/04/12
Source: System
Zone/Parameter: 0
11:32:20 Event Ready enter
0
Status:OK
Zone/Sub-code:
1. From the Home Display touch
Master
Controls
2. Touch System, then Administration.
3. Touch Display/Save Diagnostics and select which event log option you
want to filter for viewing purposes only.
4. Touch Next to continue. The events are displayed in the Display/Save
Diagnostics screen.

Advanced Software Melter Configuration
7-42
Part 1121836_03
E 11/2014 Nordson Corporation
Creating the EventLog and Diagnostic Files
Use the Display/Save Diagnostics to do the following:
S
Create a csv version of the event log, allowing you to easily view the file
in most any spreadsheet program. Refer to Using the EventLog.csv for
more information.
S
Create a diagnostic file that you can send to your Nordson service
representative to help resolve melter issues. Refer to Using the
diagnostic.nor file for more information.
NOTE: To make use of the saved log files, you must have a computer with
an SD Card device with Read/Write capabilities.
Back
Done
Display/Save Diagnostics
Save File
Home
05/04/12
Source: System
Zone/Parameter: 0
11:52:20 Event Ready enter
0
Status:OK
Zone/Sub-code:
05/04/12
Source: System
Zone/Parameter: 0
11:52:50 Event Ready enter
0
Status:OK
Zone/Sub-code:
05/04/12
Source: HMI
Zone/Parameter: 17
11:40:03 Event Zone control off
0
Status:OK
Zone/Sub-code:
05/04/12
Source: System
Zone/Parameter: 0
11:32:20 Event Ready enter
0
Status:OK
Zone/Sub-code:
1. From the Home Display touch
Master
Controls
2. Touch System, then Administration.
3. Touch Display/Save Diagnostics and select the Complete Event Log
option. The entire event log is saved regardless of which filter you
selected.
4. Touch Next, then touch Save File. A message box appears confirming
when the files have been saved to the Customer SD Card.
5. Switch the melter Off, and disconnect the electrical power to the melter at
the local power source. Open the door to access the CPU board.

Advanced Software Melter Configuration
7-43
Part 1121836_03
E 11/2014 Nordson Corporation
6. Refer to Figure 7-1 to locate and remove the Customer SD card from the
LCD module, then place it into the SD Card device connected to your
computer. By default, the following files are created:
File Name Description
EventLog.csv Provides shop technicians a quick and easy way to
troubleshoot melter issues by viewing recent
Parameter/Set Point changes, as well as Faults and
Alerts events.
NOTE: You can view the file in most any
spreadsheet program.
Diagnostic.nor Provides your Nordson service representative the
ability to view the EventLog data, along with
additional embedded melter software and hardware
data to help resolve melter issues.
NOTE: You will not be able to view this file. Contact
and email this file to your Nordson service
representative.
Using the EventLog.csv File
All events, regardless of which filter you selected, is saved the EventLog.csv
file located on the Customer SD Card.
1. Refer to Figure 7-1 to locate and remove the Customer SD card, and
place it into your SD Card device connected to your computer.
2. Access the SD Card and locate the EventLog.csv file. You can use most
any spreadsheet program to view this file.
3. When done, replace the Customer SD card back to the melter. Close the
access door, connect the electrical power to the melter at the local power
source, then switch the melter On.
NOTE: The maximum file size is limited to 500 kB or approximately 5,600
events.
Additional Event EventLog.csv Information
When the EventLog.csv initially exceeds its 500 kB file size limit, the
following happens:
S
The EventLog02.csv file is automatically created, and now it saves
the new event log data.
S
The EventLog.csv file stores the old event log data.
When the EventLog02.csv file exceeds its 500 kB file size limit, the following
happens:
S
The EventLog.csv file is automatically cleared of it old event log data,
and now it saves the new event log data.
S
The EventLog02.csv file stores the old event log data.
S
The pattern repeats itself, where the two csv files swap between
saving new event log data and storing old event log data.