Hardware Operation 4-5 Part 1121836_03 E 11/2014 Nordson Corporation Lowering Platen When lowering th e platen into a n adhesive contai ner, you must always deaerate o r let any ai r escape from under the platen. 1. Set …

100%1 / 230
Hardware Operation
4-4
Part 1121836_03
E 11/2014 Nordson Corporation
Raising the Platen when there is a Container
To prevent damage to the sealing rings, make sure you do the following
steps when attempting to raise the platen from an adhesive container.
Step 1 - Make sure the platen is hot enough so that none of the adhesive
sticks to it. From the Home screen, touch the Platen button then Adjust Set
Point.
Step 2 - Use compressed air from beneath the platen to help the heated
platen raise itself up. This process is called Aerating the Container. The
following section details this procedure in greater detail.
Aerating Container
WARNING! Risk of injury! Do not use an external source of compressed air
for aeration. Excessive pressure could damage both the platen the adhesive
container.
1. Make sure the selector Raise/lower platen (2) is set to 0.
2. Remove the rod (4) out of the aeration connection.
3. Secure the aeration tube (3).
4. Open the shutoff valve Compressed air to aerate container (1).
5. Set selector Raise/lower platen to Raise.
Hardware Operation
4-5
Part 1121836_03
E 11/2014 Nordson Corporation
Lowering Platen
When lowering the platen into an adhesive container, you must always
deaerate or let any air escape from under the platen.
1. Set selector Raise/lower platen (1) to Lower.
2. Place a drip pan under the air relief valve (3).
3. Unscrew the rod (2) somewhat to open the air relief valve.
4. Press both buttons on the two-hand control at the same time (within 0.5
seconds) until the platen is inside of the container. The downward motion
continues on its own now.
5. Close air relief valve when material flows out free of bubbles: Screw the
rod back into place.
6. Properly dispose of material according to local regulations.
Hardware Operation
4-6
Part 1121836_03
E 11/2014 Nordson Corporation
Purging Bulk Melter
You must remove or purge this material before you can use the melter in a
production environment.
Test material was used for testing prior to shipping the melter. There may be
some of the test material on the melting plate and in the pump. Place a
container under the applicator and run the pump until you no longer see the
test material.