AltaPail II Bulk Melters Product Manual.pdf - 第135页

Advanced Software Me lter Configuration 7 -49 Part 1121836_03 E 1 1/2014 Nordson Corporation Default User Settings and Ranges The following detai ls default settings and ranges for user definable me lter, temperature, pu…

100%1 / 230
Advanced Software Melter Configuration
7-48
Part 1121836_03
E 11/2014 Nordson Corporation
Locking Out Communications
Use Lockout Communication to prevent remote access to the melter while
you are troubleshooting or performing maintenance on the melter.
Administration
Done
Home
System Reset
Display/Save Diagnostics
Recipes
Lockout Communication
Reset Password Display System Data
Off
1. From the Home Display touch
Master
Controls
2. Touch System, then Administration.
3. Touch the Lockout Communication button to toggle it On or Off
4. Touch Done.
Advanced Software Melter Configuration
7-49
Part 1121836_03
E 11/2014 Nordson Corporation
Default User Settings and Ranges
The following details default settings and ranges for user definable melter,
temperature, pump and melter settings.
Temperature Settings
Setting Default Range/Option
Temperature Limits
Over Temp: 15_C (25_F) Minimum: 5_C (10_F)
Maximum: 60_C (110_F)
Under Temp: 25_C (50_F) Minimum: 5_C (10_F)
Maximum: 60_C (110_F)
Ready Delay 60 minutes Minimum: 0 minutes
Maximum: 60 minutes
Automatic Standby Disabled Enabled
Disabled
Auto Standby Start Time 0 minutes Minimum: 0 minutes
Maximum: 1,440 minutes
Auto Heaters Off Time in Auto
Standby Mode
60 minutes Minimum: 0 minutes
Maximum: 1,440 minutes
Auto Exit Standby Time Disabled Enabled
Disabled
Auto Exit Heaters Off Time in
Auto Manual Mode
0 minutes Minimum: 0 minutes
Maximum: 180 minutes
Standby Temp 50_C (100_F) Minimum: 5_C (10_F)
Maximum: 60_C (110_F)
For Melters:
7407039, 7407040, 7407041. 7407042, 7407668 and 7407669
Setting Default Range/Option
External Zones Set Point 176_C (350_F) Minimum: 40_C (100_F)
Maximum: 176_C (350_F)
Internal Zones Set Point 176_C (350_F) Minimum: 40_C (100_F)
Maximum: 176_C (350_F)
Global Set Point 176_C (350_F) Minimum: 40_C (100_F)
Maximum: 176_C (350_F)
For Melters:
7407664, 7407665, 7407666, 7407667, 7407670 and 7407671
Setting Default Range/Option
External Zones Set Point 232_C (450_F) Minimum: 40_C (100_F)
Maximum: 232_C (450_F)
Internal Zones Set Point 232_C (450_F) Minimum: 40_C (100_F)
Maximum: 232_C (450_F)
Global Set Point 232_C (450_F) Minimum: 40_C (100_F)
Maximum: 232_C (450_F)
Advanced Software Melter Configuration
7-50
Part 1121836_03
E 11/2014 Nordson Corporation
Pump Settings
Setting Default Range/Option
Operation Mode Manual Manual
Gear-to-Line
* Pressure Control
* Flow Control
NOTE: *Requires additional
hardware
Pump RPM 0 Minimum: 0 RPM
Maximum: 94 RPM
Auto Pump Off Off
On
Remote Control None set Off
On