AltaPail II Bulk Melters Product Manual.pdf - 第137页

Advanced Software Me lter Configuration 7 -51 Part 1121836_03 E 1 1/2014 Nordson Corporation Melter Settings Setting Default Range/Option Service Interval 500 hou rs M inimum: 0 hours Maximum: 876 0 hours Scheduler No ev…

100%1 / 230
Advanced Software Melter Configuration
7-50
Part 1121836_03
E 11/2014 Nordson Corporation
Pump Settings
Setting Default Range/Option
Operation Mode Manual Manual
Gear-to-Line
* Pressure Control
* Flow Control
NOTE: *Requires additional
hardware
Pump RPM 0 Minimum: 0 RPM
Maximum: 94 RPM
Auto Pump Off Off
On
Remote Control None set Off
On
Advanced Software Melter Configuration
7-51
Part 1121836_03
E 11/2014 Nordson Corporation
Melter Settings
Setting Default Range/Option
Service Interval 500 hours Minimum: 0 hours
Maximum: 8760 hours
Scheduler No events defined Minimum: 2 events per day
Maximum: 12 events per day
Password Protection No Password Protection High
Medium
Low
No Password Protection
Password Level Codes Level 1: 1000
Level 2: 2000
Level 3: 3000
Minimum: 1
Maximum: 65535
NOTE: Code levels must be
unique.
Password Timeout 1 minute Minimum: 1
Maximum: 60
Display Brightness/Contrast 75% | 75% Minimum: 30%
Maximum: 100%
Display Screen Saver Delay 1 minute Minimum: 1 minute
Maximum: 120 minutes
RTD Options NI120 NI120
Lockout Communications Off Off
On
Inputs/Outputs
Inputs Inputs:
#1: Automatic Standby
#2: Standby
#3: Heater Control
#4: External Zone # A/B
Disabled
Standby
Heater Control
Pump (Control)
External Zone # A/B
Automatic Standby (Available
only for Input #1
Outputs Outputs:
#1: Ready
#2: Fault
#3: Tank Low
Disabled
Ready
Ready-Pump On
Fault
Tank Low
Alert
Service Reminder
Maintenance
8-1
Part 1121836_03
E 11/2014 Nordson Corporation
Section 8
Maintenance
WARNING! Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
NOTE: Maintenance is an important preventive measure for maintaining
operating safety and extending the service life of the unit. It should not be
neglected under any circumstances.
Risk of Burns
Some maintenance work can only be done when the bulk melter is heated
up.
WARNING: Hot! Risk of burns. Wear safety goggles and heat-protective
gloves.
Relieving Pressure
WARNING: System and material pressurized. Relieve bulk melter pressure
before disconnecting pressurized components (e.g. hoses, pressure
sensors). Failure to observe can result in serious burns.
1. Switch the pump off.
2. Set selector Raise/lower platen to 0.
3. Place a container under the nozzle(s) of the applicator/assembly
handgun.
4. Applicators: Activate the solenoid valve(s) electrically or manually; or, pull
the trigger of the assembly handgun. Repeat this procedure until no more
material flows out.
5. Re-use the material or properly dispose of it according to local
regulations.