126/144 8.6.9 Bits for P_VPC_DEST (si.par) 0x1 create VPC files 0x2 create VPC files for single barcodes 8.6.10 Bits for P_VPC_USE (rep.par) 0x1 update VPC files 0x2 update VPC files for single barcodes 0x4 do not enter …

125/144
8.6.8 Utility Si_cad_sort_mfc
For more detailed information, see Viscom Online Help.
1 selecting a path to the inspection plan
2 path to the where the list is saved
3 edits the list as notepad
4 component forms in the inspection plan
5 paste
6 cancel
1
2
3
4
6
5

126/144
8.6.9 Bits for P_VPC_DEST (si.par)
0x1 create VPC files
0x2 create VPC files for single barcodes
8.6.10 Bits for P_VPC_USE (rep.par)
0x1 update VPC files
0x2 update VPC files for single barcodes
0x4 do not enter group serial defects in VPC files
0x8 do not enter repair name in VPC files

127/144
8.6.11 Entries in si.tpar
For the Repair Station default
TPAR_VPC_FAILED R:\VPC\INPUT
TPAR_REP_WORK R:\WORK
For the VPC Server default
TPAR_VPC_PASSED S:\WORK
8.6.12 Operator filter
This filter allows filtering according to the operator ID, if this feature is
configured on the repair station.
8.6.13 Bond filter
The bond filter allows filtering according to bonder numbers. This filter can only
be used with bond inspection.