1.011.1_VPC使用手册.pdf - 第44页

43/144

100%1 / 145
42/144
After a short evaluation time, a new configuration set with two Pareto diagrams
opens automatically. These templates are pre-configured diagrams that can be
called up from other diagrams. The vpc.template file underlies them, the
possible branchings can be configured here (see appendix for a more detailed
description).
These files should only be edited by experienced users, otherwise faulty results
or a loss of functions in the cascaded evaluations may result.
In these diagrams, it can be seen that the time filter as well as the inspection
plan filter are automatically taken over from the time axis diagram.
Both templates are preconfigured so that the pseudo defects are seen on the
left side and the real defects, on the right.
This display always makes sense during optimization, to observe not only the
inspection patterns with regard to the pseudo defects they produce, but also
their effectiveness in relation to real defect recognition.
In our example the component type 0603R is to be optimized as TOP 1.
43/144
44/144
Additional information in the Pareto diagram:
1 time filter (the set evaluation period is displayed)
2 program filter (the inspection plan set in the filter is displayed)
3 component filter (not set, and so marked with */*)
4 machine filter (not set, and so marked with *)
5 operator filter (not set, and so marked with *)
6 features filter (due to lack of space only the first filter entry is displayed;
the fact that others follow is recognized by the ellipses [,...])
7 total number of evaluated PCBs / indication of defective PCBs, result in
% (can also be switched to single panel display, in diagram properties)
8 total number of evaluated components / indication of defective
components, result in %. If a value is 0, the file si_sj.cnt or the CLE
entry #CLE_PINS is not maintained.
9 total number of evaluated solder joints / indication of defective solder
joints, result in PPM. If a value is 0, the file si_sj.cnt or the CLE entry
#CLE_PINS is not maintained.
The component type 0603R is responsible for a lot of pseudo defects, but which
analyses is it made up of? In order to get more precise information, the
9
3
8
7
2 1
6 4
5