128/144 8.6.14 Barcode filter The barcode filter allows filtering according to one or more barcodes. 8.6.15 Parameters for vpc.ini Parameter assignment: si_spc.par vs. Vpc.ini New parameter (VPC) Section Name Value Entry…

100%1 / 145
127/144
8.6.11 Entries in si.tpar
For the Repair Station default
TPAR_VPC_FAILED R:\VPC\INPUT
TPAR_REP_WORK R:\WORK
For the VPC Server default
TPAR_VPC_PASSED S:\WORK
8.6.12 Operator filter
This filter allows filtering according to the operator ID, if this feature is
configured on the repair station.
8.6.13 Bond filter
The bond filter allows filtering according to bonder numbers. This filter can only
be used with bond inspection.
128/144
8.6.14 Barcode filter
The barcode filter allows filtering according to one or more barcodes.
8.6.15 Parameters for vpc.ini
Parameter assignment: si_spc.par vs. Vpc.ini
New parameter (VPC)
Section Name Value
Entry no. Description
Debug DumpData 0/1 1 read out data for the
diagram and file lists in
the file
Settings Language 0-3 2 choice of language to
be used
Directories Work Directory 3 choice of source
directory
Directories Work2 Directory 4 choice of 2nd source
directory
Directories Work3 Directory 5 choice of 3rd source
directory
Settings SkipGroupErrors 0/1 6 skip unrepaired and
group defects
129/144
diagram-specific via status filter 7 Skip unrepaired PCB
Settings AnalyzeOnSelection 0/1 8 start data evaluation
automatically when
diagram is chosen
Export enabled 0/1 9 activate writing of export
files
Export HideErrors 0/1 10 do not export defects
Export Append 0/1 11 do not re-create file, but
attach to end
Export WriteFilename 0/1 12 export VPC file names
Export WriteBonderNr 0/1 13 export bonder number
Export WriteGoodPcb 0/1 14 export short entry for
good PCB
Export UseSemicolon 0/1 16 separate columns with
semicolons
Export WriteProdNr 0/1 17 export order number
Export WriteBarcode 0/1 18 export barcode
Export HideFeatures 0/1 19 do not export
measurement values
Export WriteLineNr 0/1 20 export line number
Settings OneErrorPerSj 0/1 21 count one defect per
solder joint
Settings AutoPrint 0/1 22 print out diagram after
data evaluation
Limit LogDaily 0/1 23 log exceeded limit
values by day