00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第101页

3 Power supply 3.5 Power supply and transformer module (from serial number Hxxxx) Service Manual SIPLACE X-Serie S 06/2019 101 3.5.12.1 Distribution and fusing board assembly Fig.120: Distribution and fusing board assem…

100%1 / 428
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
100 Service Manual SIPLACE X-Serie S 06/2019
3.5.12 Replacing the Distribution and Fusing Assembly
Parts, equipment and tools
Distribution and fusing board assembly [03118289‑xx]
Overview
Fig.118: Distribution and fusing board assembly
1. Distribution and fusing board assembly
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.5.4 "Checking For
Absence of Voltage" [}86].
Unplug all electrical connections to the board. You might like to mark their positions to make
clear assignment easier later on.
3.5.12.1 "Distribution and fusing board assembly" [}101]
Fig.119: Fastening screws
Remove the fastening screws on the
board and the ground conductor.
Remove the board.
Installation
Follow the removal instructions in reverse order for installation.
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
Service Manual SIPLACE X-Serie S 06/2019 101
3.5.12.1 Distribution and fusing board assembly
Fig.120: Distribution and fusing board assembly [03118289‑xx]
Micro fuse 5x20mmT 6.3A 250V (spare part) [03078843‑xx]
Each machine is supplied with a pack of 10 fuses.
CAUTION
Use only 6.3A fuses!
If 10A fuses are present, replace them by 6.3A fuses.
3 Power supply
3.5 Power supply and transformer module (from serial number Hxxxx)
102 Service Manual SIPLACE X-Serie S 06/2019