8 Head exchange
8.1 Fast Hardware Exchange
Service Manual SIPLACE X-Serie S 06/2019 307
8.1.2 Removing and Installing the Placement Head
For actually removing and installing the placement head hardware, proceed as described in
the relevant chapter.
8.3 "Replacing the SIPLACE C&P20/A/M" [}310]
8.5 "Replacing the SIPLACE C&P20P/M2" [}313]
8.6 "Replacing the SIPLACE CPP/M" [}316]
8.1.3 Completing the FHE in the Software
Switch the machine on.
After being switched on again the machine issues the message Changed heads detected and ex-
pects a calibration.
Fig.392: Select operator level
Select the
button, to open the
Configure, update and calibrate the
machine menu.
Select the
button to open the
Check and set user settings menu.
Switch over to the operator level Ma-
chine service.
ð The
button will be shown.
Fig.393: Service menu
Select the Service
button.
Select the Fast hardware exchange
button.
8 Head exchange
8.1 Fast Hardware Exchange
308 Service Manual SIPLACE X-Serie S 06/2019
Follow the instructions on the screen for all further steps.
NOTICE
Nozzles
In the event of repairs, it is not always possible to simply return the nozzles from a defective
head to the nozzle changer in order to achieve a defined state. It may not be possible at all
to achieve a defined state. After the head exchange the software stores the nozzle config-
uration of the defective head and the nozzle changer. You can then refill the garages to re-
store the same level as before the head failure.
If the newly fitted head is equipped with calibration nozzles, these will either be placed in
empty nozzle garages or rejected after the calibration. The nozzles required for the job can
then be picked up and the production can be started.
You can also skip refilling the garages. In this case you have to refill the nozzle changer be-
fore the start of the production.
NOTICE
Not enough calibration tools
If there is no calibration tool present for each head, click on the Cannot supply all
calibration tools at once button. Depending on your machine type you may be
prompted to provide the calibration tool for each head individually.
If there is an empty magazine in the machine after the calibration has been completed, select
the Remove calibration nozzlesbutton.
Select the Finish button.
If there are any problems during the reference run (vacuum check), perform zero correction
for the pressure control valve.
The exchange has now been completed and production can be restarted.
8 Head exchange
8.2 Differentiation of the SIPLACE C&P20 head variants
Service Manual SIPLACE X-Serie S 06/2019 309
8.2 Differentiation of the SIPLACE C&P20 head variants
CAUTION
Do not confuse the different SIPLACE C&P20 head variants.
Parts from the SIPLACE C&P20/A/M head can not usually be used for the SIPLACE
C&P20P/M2 head (and vice versa)!
Fig.394: Differentiation of the SIPLACE C&P20 head variants
The SIPLACE C&P20/A/M and the SIPLACE C&P20 P/M2 head differ in many details. They are
easily identified by the following features:
1. The SIPLACE C&P20 P/M2 head can be identified by the fan. This fan is not present on the
SIPLACE C&P20/A/M.
2. The component sensor is flatter and wider on the SIPLACE C&P20 P/M2 than on the
SIPLACE C&P20/A/M.