00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第385页

9 Component feeding 9.4 Docking Station for Component Trolley Service Manual SIPLACE X-Serie S 06/2019 385 Overview 1 2 Fig.519: Locking lever left and right 1. Locking lever – on the left side 2. Locking lever – on the…

100%1 / 428
9 Component feeding
9.4 Docking Station for Component Trolley
384 Service Manual SIPLACE X-Serie S 06/2019
Removal
Fig.517: Removing the locking unit
 CAUTION!
Risk of injury
Risk of injury when disconnecting
pressurized compressed air lines.
.
Switch off the compressed air supply.
Remove the pneumatic connections on
the short-stroke cylinder.
Remove the two screws (1) fastening
the short-stroke cylinder (2).
Pull the short-stroke cylinder and the
locking slider(3) downwards and out of
the guidance block(5).
Unscrew the locking slider from the
short-stroke cylinder(2).
Installation
Fit the locking slider onto the new short-stroke cylinder.
Clean the locking sliders and the guidance block with a clean, lint-free cloth and lubricate both
slightly with Unisilikon.
Move the locking slider into the guidance block, so that the beveled side (4) is pointing to the
front (in the direction of travel). This is important when moving the component trolley in.
Fit the short-stroke cylinder with the two fastening screws.
Reconnect to the compressed air supply.
Switch the compressed air supply on and check that the left and right locking sliders move out
at the same time.
If necessary, adjust the throttle valve on the short-stroke cylinder.
9.4.5 Replacing the locking lever
Parts
Fig.518: Horizontal tensioner
03025104-xx Horizontal tensioner DE-STA-CO 225-U
Equipment and tools
00353832-xx Allen key set
9 Component feeding
9.4 Docking Station for Component Trolley
Service Manual SIPLACE X-Serie S 06/2019 385
Overview
Fig.519: Locking lever left and right
1. Locking lever – on the left side
2. Locking lever – on the right side
Removal
Fig.520: Removing the locking lever
1. Locking lever
2. Four fixing screws
3. Position end switch
4. Limit switch
Remove the four screws(2) (twoeach
at the top and bottom) fastening the
locking lever(1).
Remove the locking lever.
Installation
Loosely screw in the new locking lever.
Align the locking lever to the edge (3) and tighten the four fastening screws.
Check that the limit switch (4) is actuated when the locking lever is closed. Correct the posi-
tion of the locking lever if necessary.
Check the position end switch function by trying out the locking procedure.
9 Component feeding
9.4 Docking Station for Component Trolley
386 Service Manual SIPLACE X-Serie S 06/2019
9.4.6 Replacing the positions end switch of the component trolley locking device
Parts
03033395-xx Position end switch
Equipment and tools
00353832-xx Allen key set
Wire cutters
Cable ties
Overview
Fig.521: Position end switch left and right
1. Position end switch – on the left side
2. Position end switch – on the right side
Removal
Fig.522: Removing the position end switch
1. Position end switch with connection
cable
2. Two fastening screws
3. Connection cable to connector unit
4. Actuation by locking lever
 DANGER!
Switch off the voltage supply
Press the ON/OFF button to switch off
and then unplug the power supply.
.
Remove the two screws fastening the limit switch.
Open the casing of the connector at the back and label the terminal connections.
NOTICE
Connector for left and right position end switch
The connection cables for the left and right position end switch are connected to a
common connector.
Disconnect the connection cable for the relevant position end switch, in the connector.
Unthread the connection cable and remove the position end switch.