6 Gantries
6.5 GCU and MGCU
Service Manual SIPLACE X-Serie S 06/2019 183
6.5 GCU and MGCU
6.5.1 Replacing the GCU
NOTICE
MGCU or GCU
GCUs and MGCUs are not compatible. A GCU must always be replaced by a GCU and an
MGCU must be replaced by an MGCU.
Only MGCUs will be fitted from serial number Hxxxx. Please read section 6.5.4 "Replacing
the MGCU" [}186].
Parts, equipment and tools
Positioning control unit for gantry axes GCU [03052200-xx]
Overview
Fig.232: Overview of GCUs
1) to 4) GCUs
The GCUs are located in a rack unit
between locations 1 and 2.
The assignment of GCUs to gantries differs
according to the machine type. Observe the
instructions in section 6.5.3 "Overview of
GCUs" [}185].
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Unplug all cables from the GCU. If necessary, mark their positions to make clear assignment
easier later on.
Remove the screws fastening the mount and then remove the mount.
Remove the GCU from the machine.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Use the DIP switch to set the gantry ID on the GCU.
6.5.3 "Overview of GCUs" [}185]
Check the firmware and perform a download, if needed.
6.9 "eSW Download (SW 70x)" [}202]
6 Gantries
6.5 GCU and MGCU
184 Service Manual SIPLACE X-Serie S 06/2019
6.5.2 Replacing the GCU fan
Parts, equipment and tools
Fig.233: Overview – fan on the GCU
1. GCU fan [03060954-xx]
2. Plastic expansion rivets
(snap rivet DRM 4x4.5-5.5 sw
SR-4070B [03106012-xx])
These are supplied with the fan.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Unplug the cable from the fan. You may want to mark the position, to make clear assignment
easier later on.
Pull out the four expansion rivets on the fan and then remove the fan.
NOTICE
Two-part expansion rivets
The expansion rivets are in two parts.
First remove the center pin. The lower part can now be easily pulled out.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
The expansion rivets are in two parts. First insert the lower part into the hole and then fix
this into place with the upper part.
6 Gantries
6.5 GCU and MGCU
Service Manual SIPLACE X-Serie S 06/2019 185
6.5.3 Overview of GCUs
Fig.234: Overview of GCUs