00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第162页

6 Gantries 6.4 Trailing cable and printed circuit boards 162 Service Manual SIPLACE X-Serie S 06/2019 6.4.1.1 Handling the hose unlocking tool Equipment and tools Fig.201: Unlocking tool ● Tool set vacuum connection X-S…

100%1 / 428
6 Gantries
6.4 Trailing cable and printed circuit boards
Service Manual SIPLACE X-Serie S 06/2019 161
Overview
Fig.198: Overview of trailing cable (in example "up to
Gxxxx", without GigE)
1. Boards on the gantry (shown without
board cover here)
2. Trailing cable console
3. Power track chain
4. Trailing interface gantry
5. Pneumatic hoses to the pneumatic dis-
tributor (in the machine base)
6. Gantry interface
7. Connection piece for cooling tubes to Y
motor
8. Vision Hotlink Adapter VHA
[03050555‑xx]
9. Pneumatic distributor
Fig.199: Boards on the gantry (up to Gxxxx, without
GigE)
Fig.200: Boards on the gantry (from Hxxxx, with GigE)
1 Vision board spread spectrum / Vision
Head Interface (VHI)
2 Head interface
3 Power cube on the head interface
6 Gantries
6.4 Trailing cable and printed circuit boards
162 Service Manual SIPLACE X-Serie S 06/2019
6.4.1.1 Handling the hose unlocking tool
Equipment and tools
Fig.201: Unlocking tool
Tool set vacuum connection X-Series
(unlocking tool) [03051867‑xx]
Consists of:
Hose unlocking tool [03047090-xx]
Unlocking tool for QSC-10H
[03051853-xx]
Usage
Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}134]
Due to the poor access to the pneumatic distributor, we recommend using the unlocking tool.
With the help of the hose unlocking tool, you can open the unlocking ring for the compressed air
connection. This enables you to remove both the hoses and the blanking plugs (additional tool "Un-
locking tool for QSC-10H" [03051853-xx]).
Fig.202: Handling the unlocking tool
Use the pipe-shaped tool (1) to open
the unlocking ring (blue here).
Carefully pull the hose or the blanking
plug(2) out of the compressed air con-
nection.
6 Gantries
6.4 Trailing cable and printed circuit boards
Service Manual SIPLACE X-Serie S 06/2019 163
6.4.1.2 Replacing the X Trailing Cable
Parts, equipment and tools
X trailing cable (see above)
Hose unlocking tool [03047090-xx]
Pipe/hose cutters [00381443-xx]
If required, assembly instructions for the "vacuum pump" [00196845‑xx]
Sealing varnish Loctite 241 [02101037-xx]
Edding marker, white [00382740-xx]
Help of second person, if needed
Assembly instructions for vacuum pump SIPLACE X-Series S, SX4/DX4, if required
[00196845-xx]
Removal
NOTICE
Vacuum pump
When a vacuum pump is fitted, also observe the assembly instructions "Vacuum pump
X-Series S, SX4/DX4" [00196845‑xx].
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Switch off the compressed air supply
5.2 "Disabling the compressed air supply" [}134]
Loosening the trailing cable on the machine side
Fig.203: Dismantling the cover
Remove the six screws fastening the
cover(1) and remove the cover.