9.4.9 Replacing the Complete Coupling - Earthing and Compressed Air for the
Bulk Case
Parts
You can either replace the individual coupling socket or the complete coupling unit for ground and
compressed air.
03017026-xx Coupling socket for compressed air coupling
03017025-xx Complete coupling for ground connection and compressed air
Equipment and tools
00353832-xx Allen key set
Overview
Fig.531: Coupling on docking station
1. Coupling socket for component trolley
compressed air coupling (bulkcase
feeder)
2. Compressed air connection to the
pneumatic control value 5.5 bar.
3. Component trolley ground coupling
(bulkcase feeder)
Removal / installation
Fig.532: Removing the coupling
1. Fastening the complete coupling
(ground and compressed air)
2. Coupling socket for compressed air
coupling
3. Mount
4. Pneumatic connection to pressure con-
trol valve 5.5 bar at the back
 CAUTION!
Risk of injury from compressed air!
Risk of injury when disconnecting
pressurized compressed air lines.
Switch off the compressed air supply.
.
Individual replacement of coupling socket for compressed air coupling
Unplug the compressed air connection.
Use an open-end wrench to unscrew the coupling socket from its mount.
Screw in the new coupling socket and connect the compressed air supply.
Switch on the compressed air supply.
Check the set pressure of 5.5 bar at the pressure control valve (located at the back).
9 Component feeding
9.4 Docking Station for Component Trolley
392 Service Manual SIPLACE X-Serie S 06/2019
Replacing the complete coupling for ground and compressed air
Unplug the compressed air connection.
Remove the fastening screw and remove the complete unit.
Fit the new assembly and reconnect the compressed air supply.
Switch on the compressed air supply.
Check the set pressure of 5.5 bar at the pressure control valve (located at the back).
9.4.10 Replacing the unlocking pushbutton
Parts
Fig.533: Pushbutton
00334095-xx Unlocking pushbutton
Equipment and tools
00353832-xx Allen key set
Wire cutters
Cable ties
Overview
Fig.534: Unlocking pushbutton on docking station
1. Unlocking pushbutton
9 Component feeding
9.4 Docking Station for Component Trolley
Service Manual SIPLACE X-Serie S 06/2019 393
Removal and installation
Fig.535: Removing the unlocking pushbutton
1. ON / OFF switch
2. Power supply plug
3. Cover
4. Bar for clamping the cover
5. Four screws fastening the cover
6. Terminal block for pushbutton
 DANGER!
Switch off the voltage supply
Press the ON/OFF button (1) to switch off
and then unplug the power supply (2).
.
Remove the four screws (5) fastening the cover (3). The cover is clamped in place with the
help of the bar (4).
Pull the cover (1) out of the docking station.
Take care not to damage the ground connection.
Remove the screw fastening the terminal block (6) of the pushbutton.
Turn the terminal block and extract it from its fixtures.
Label the connection leads and disconnect these from the terminal block.
Connect the connection cables to the new pushbutton.
Fit the new pushbutton.
Refit the cover.
Connect the power pack connection cable and press the ON/OFF button to switch on.
Check the function of the pushbutton by trying out the unlocking procedure.