9 Component feeding 9.6 Smart Pin Support 412 Service Manual SIPLACE X-Serie S 06/2019 9.6.11 Replacing the tension spring Parts, equipment and tools ● Tension spring (reduced eyelet) [03089675-xx] ● Circlip pliers size …

100%1 / 428
9 Component feeding
9.6 Smart Pin Support
Service Manual SIPLACE X-Serie S 06/2019 411
9.6.10 Replacing the Round Cable
Parts, equipment and tools
Connection cable SPS [03091099-xx]
NOTICE
Control board SPS
The new SPS connection cable and the old SPS control board are not compatible with one
another.
Replace the SPS control board if required.
Overview
Fig.564: Round cable (example of SIPLACE X‑SeriesS
shown)
1. Head interface on the gantry
2. Round cable
3. Cable ties
4. SPS control board on the Pin Picker
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Disconnect the round cable from the head interface.
Disconnect the round cable from the SPS control board.
Remove the round cable. To do this, loosen the cable ties on the round cable.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Replace the cable ties.
Make sure that the cable does not get in-between the X axis buffers.
9 Component feeding
9.6 Smart Pin Support
412 Service Manual SIPLACE X-Serie S 06/2019
9.6.11 Replacing the tension spring
Parts, equipment and tools
Tension spring (reduced eyelet) [03089675-xx]
Circlip pliers size 0 (supplier: http://www.hoffmann-tools.com – item no.:719770 J0)
Assembly instructions "Smart Pin Support" for SIPLACE X‑SeriesS [DEEN:00197394‑xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Remove the pin picker. For more information, read section 9.6.1 "Replacing the Pin Picker
Assembly" [}399].
Remove the linear guide. For more information, read section 9.6.4 "Replacing the linear
guide" [}403]. You do not need to remove the front and back sections of the cylinder.
Fig.565: Tension spring
Loosen the circlip on the holding
bolt(1) of the tension spring(2) and
then pull out the holding bolt.
Remove the tension spring.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
When you screw in the linear guide carriage, press it to the left, against the stop edge, so
that it lies flush against the base plate.
9 Component feeding
9.6 Smart Pin Support
Service Manual SIPLACE X-Serie S 06/2019 413
9.6.12 Replacing the top sensor
Parts, equipment and tools
Top sensor [03093273Sxx]
Assembly instructions "Smart Pin Support" for SIPLACE X‑SeriesS [DEEN:00197394‑xx]
Overview
Fig.566: Sensors
1. Control board
2. Fastening screw for top sensor
3. Fastening screw for bottom sensor
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Remove the pin picker. For more information, read section 9.6.1 "Replacing the Pin Picker
Assembly" [}399].
Fig.567: Screws fastening the guide
Remove the two screws(2) fastening
the pneumatic cylinder guidance(1).
Remove the screws holding the sensor.
Unthread the sensor cable as far as the
board. Open the corresponding cable
ties to help you, if needed.
Unplug the sensor cable from the
board. You may want to mark the posi-
tion to make clear assignment easier
later on.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Fasten the sensor in the center of the slot.
Replace any opened cable ties.