00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第370页

9 Component feeding 9.2 COT insert 370 Service Manual SIPLACE X-Serie S 06/2019 Removal CAUTION Do not dismantle the empty tape duct Only the empty tae duct Einsatz may be replaced. Dismantling the empty tape duct is not…

100%1 / 428
9 Component feeding
9.2 COT insert
Service Manual SIPLACE X-Serie S 06/2019 369
9.2.10 Replacing the empty tape duct Einsatz
Read the relevant section of the user manual for your machine.
Parts, equipment and tools
Empty tape duct Einsatz
(The number can be found in catalog of parts.)
Overview
Fig.493: Empty tape duct (example of SIPLACE X‑Series
shown)
1. Empty tape duct assembly
2. Empty tape duct Einsatz
Fig.494: Empty tape duct Einsatz (example of SIPLACE
SX4 shown)
1. Empty tape duct
2. Screws fastening the empty tape duct
Einsatz (left and right)
9 Component feeding
9.2 COT insert
370 Service Manual SIPLACE X-Serie S 06/2019
Removal
CAUTION
Do not dismantle the empty tape duct
Only the empty tae duct Einsatz may be replaced. Dismantling the empty tape duct is not
permitted.
NOTICE
Inner empty tape duct Einsatz
When using tape reels with deep pockets, you may need to remove the inner baffle. Refer
to the operating manual of your machine for details.
All screws are accessible in the installed state. The baffles can therefore be replaced inside
the machine.
Remove the two screws fastening the empty tape duct Einsatz and remove these.
Installation
Installation is performed by following the above instructions in the reverse order. Also observe
the following instructions:
Refit the empty tape duct Einsatz on the empty tape duct if you are not using any compon-
ents >15mm.
CAUTION
The empty tape duct Einsatz fits somewhat tightly in the empty tape duct
These can damage the coating in the empty tape duct, which can then lead to component
tapes getting jammed at the edges. This could then cause a head crash.
Never use sharp-edged objects to position the empty tape duct Einsatz.
If necessary, use a wooden wedge or, as shown in the following diagram, a brush with
wooden handle.
Fig.495: Empty tape duct
9 Component feeding
9.2 COT insert
Service Manual SIPLACE X-Serie S 06/2019 371
9.2.11 Replacing the infeed control
Parts, equipment and tools
Fig.496: Feed control
1. Infeed control assembly SX4
[03082077-xx]
Removal
Switch off the machine and secure it to prevent unauthorized reactivation. Observe the
instructions in section 1.2 "Preparatory work..." [}16].
Dismantle the nozzle changer over the infeed control (see 2.8.2 "Replacing the Nozzle
Changer" [}44]).
To gain better access, you may need to disconnect the COT insert and pull it slightly out of
the machine. Observe the instructions in section 9.2.2 "Installation Positions of COT Insert and
Manual Table (Table Positions)" [}356].
Alternatively, you can improve access by removing the upper section of the component cam-
era.
CAUTION
Component camera
The component camera mirror has sharp edges.
Take care not to damage the component camera.
Unplug all electrical connections to the insert control. You may want to mark their positions, to
make clear assignment easier later on.
Remove the screws fastening the infeed control and remove the insert control from the
machine.
Installation