00197042-04_SM_X-Serie-S_Customer_EN.pdf - 第154页

6 Gantries 6.3 X and Y axis 154 Service Manual SIPLACE X-Serie S 06/2019 6.3.8.1 Test device – operation Test device PG1-I [03102699‑xx] Fig.191: Operation of test device PG1-I - 1

100%1 / 428
6 Gantries
6.3 X and Y axis
Service Manual SIPLACE X-Serie S 06/2019 153
6.3.8 Track Signals and Zero Pulse
Equipment and tools
Fig.189: Test devices PG1-I and PG-U
For MS22/25 incremental encoder: test device PG1-I [03102699‑xx]
For MS20/30/35 incremental encoder: test device PG-U [03071361‑xx]
Checks
Proceed as follows to check the zero pulse:
Switch off the machine.
Fig.190: Test device (example of test device PG-U on a SIPLACE SX1 shown)
Unplug the incremental encoder from the head interface or the gantry interface and connect it
to the test device (see also 6.3.8.1 "Test device – operation" [}154]).
Move the head or gantry manually back and forth. This movement enables you to read the
correct track signal progress from the test device.
If the track signal is not within the tolerance range, you will need to reset the incremental en-
coder. The incremental encoder has then been fitted either too near, too far away, inclined
and/or displaced.
6 Gantries
6.3 X and Y axis
154 Service Manual SIPLACE X-Serie S 06/2019
6.3.8.1 Test device – operation
Test device PG1-I [03102699‑xx]
Fig.191: Operation of test device PG1-I - 1
6 Gantries
6.3 X and Y axis
Service Manual SIPLACE X-Serie S 06/2019 155
Fig.192: Operation of test device PG1-I - 2