3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
60 Service Manual SIPLACE X-Serie S 06/2019
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
Unplug all connections to the module. You may want to mark their positions, to make clear as-
signment easier later on.
Fig.59:
To release the module, press the lever
(1) at the back of the module down and
then pull the module off the rail.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
Set the voltage (see 3.4.8.1 "Setting the Voltage on the AC/DC Converters" [}61]).
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
Service Manual SIPLACE X-Serie S 06/2019 61
3.4.8.1 Setting the Voltage on the AC/DC Converters
Parts, equipment and tools
Voltage measuring device
Overview
Fig.60: AC/DC converter
The AC/DC converters are located in the
rack unit between location 3 and 4.
A5) AC/DC converter (24 VDC, set to 25
VDC)
for Power Fail, safety circuit SSK, tape cut-
ter, PCB handling
The power fail signal is generated by the
AC/DC converter A5 and sent to the GCU
and HCU. (X200:9, X200:10)
A6) AC/DC converter (27 VDC)
for FCU (gantry 1 and 4)
A7) AC/DC converter (27 VDC)
for FCU (gantry 2 and 3)
A8) AC/DC converter (36 VDC, set to 42
VDC)
for HCU (gantry 1 to 4)
CAUTION
Check the values
Check the set values and correct if necessary.
To A5:
There is 24V present at the following fuses:
F10 Conveyor electrics F11 Y motor fan, safety circuit (internal)
F12 Distributor power (line 1) F13 Distributor power (line 2)
F14 Power fail F20 Cover fan gantry 1 and 4
F21 Cover fan gantry 2 and 3
Setting
Fig.61: Setting the voltage
Open the protective cap on the setting
screw(1).
Use a flat-bladed screwdriver to set the
correct voltage on the AC/DC con-
verter.
Check the voltage with a suitable
voltage measuring device between the
terminals + and.
3 Power supply
3.4 Power supply and transformer module (up to serial number Gxxx)
62 Service Manual SIPLACE X-Serie S 06/2019
3.4.9 Replacing the Rectifiers (U1 to U3, U20 to U24)
Parts, equipment and tools
U1, U3: rectifier S101-B6U 160-08 [00341246-xx]
U2: rectifier S61-B2U 28-10 [03080931-xx]
U20 to U24: rectifier S61-B2U 28-04 [03079959-xx]
Silicon-free heat-conductive paste (not electrically conductive)
Thermal conductivity 1.0 W/mK
Dielectric strength 40kV/mm
Temperature range -40°C to +200°C
Flash point >280°C
Suggested supplier: Bürklin OHG, order number 80 B 531
Overview
Fig.62: Rectifiers
1. Cover
2. Rectifier U24
3. Rectifier U3
4. Rectifier U1
5. Rectifier U2
6. Rectifier U20 to U23
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
Remove the screws fastening the cover and swing the cover towards the front. The AC/DC
converters are also fitted on the cover. These are swung away with the cover.
Unplug all connections to the rectifiers. You may want to mark their positions, to make clear
assignment easier later on.
Remove the screws fastening the rectifier and remove the rectifier.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions: