DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第199页
7-35 Part Registration <Supply Angle> group <Supply Angle> combo box Sets the angle at which a part is supplie d based on the No. 1 pin position of the part. Set the 3 o’clock d irection to 0° and increas…

7-34
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
<Direction Check> tab screen
Applied to IC parts and ball parts in the same manner.
<Body Polarity> combo box
Set the polarity of the body whose direction is to be checked.
Don’t care: Selected when recognizing the body whose direction is to be
checked regardless of the polarity.
Dark On Light: Selected when the body whose direction is to be checked
is darker than the background.
Light On Dark: Selected when the body whose direction is to be checked
is brighter than the background.
<Body Score Threshold> edit box
Set the threshold of the body whose direction is to be checked. (0~100).
<Body Sub Sample> edit box
Set the degree of sampling of the body whose direction is to be checked.
(0~10, 0: auto).
<Max Offset[100um]> edit box
Set the maximum allowable error of the body whose direction is to be
checked. (0~10).
<1st Pin Position> button
Used to check the placement angle easily when verifying the placement point offline
by registering the No. 1 pin position when registering a part.

7-35
Part Registration
<Supply Angle> group
<Supply Angle> combo box
Sets the angle at which a part is supplied based on the No. 1 pin position of the
part.
Set the 3 o’clock direction to 0° and increase the angle by 90°
counterclockwise.
<Supply Angle Verified> check box
If this checkbox is selected after checking that the supply angle is set
correctly, it indicates that the set supply angle is effective.
<1st Pin Detail> group
<Orientation> combo box
Sets the direction of the No. 1 pin of the part. For chip parts, a pad is regarded
as a pin.
Set the 3 o’clock direction to 0° and the angle increases by 90°
counterclockwise.
<Pin Index> combo box
For IC parts, when designating the number for the leads at one side, the
number is assigned from “0” from right to left in order.
<1st Pin Position Verified> check box
If this check box is selected after checking that the No. 1 pin position is set
correctly, it indicates that the information on the set No. 1 pin is effective.
<Update> button
Reflects the changes.
<Outline> button
Shows the image seen through the Vision in real display to which threshold is not
applied, or in the image (Binary) to which threshold is applied as recognized by MMI.

7-36
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
<Move> button
Used for parts recognition test by manually picking up parts. When this button is
clicked on, the following dialog box is displayed.
<Device> combo box
Select the camera to be used for parts recognition.
Only when “Fix Cam1” is selected from the <Camera No.> combo box in the Edit
Part dialog box will the “Align Test” be executed.
<Align Z> edit box
Set the height for recognition. Based on the component surface, if the top is to be
recognized, set - value, and if the bottom is to be recognized, set +value.
<Action> group
<Prepare Manual Pick> button
Moves the head block to the pick-up position when the component is to be
picked to the head manually. Moves to the Home position of the equipment.
<Prepare Align Test> button
When the camera recognizing parts is “Fly Camera”, move the height of the
Z-axis at the tip of the nozzle installed at the head to the align height, close
mirror, and illuminate the part.
When the camera recognizing the parts is “Fix Camera”, move the height of
the Z-axis at the tip of the nozzle installed at the head to a safe height, move
the head assembly to the position of fix camera, and move the Z-axis height at
the tip of the nozzle to the part recognition height (align height).
<Vacuum ON/OFF> button
Turns on/off the vacuum generator of the head for the component pick-up or