DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第301页
9-7 Step Programming <Filtering> button Indicates only the placement point that is filtered according to the condition selected from the <Filte r> combo box in the “Steps” di alog box. button <None&g…

9-6
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
<Array No.> combo box
Selects an array among the arrays for which placement point is to be indicated.
<Extend> check box
Displayed only in the case of Array PCB. Expand the placement point to one PCB
by using the offset value of array PCB.
For example, if the number of current placement points is 10 and the number of
array PCB is 4, then the total number of placement points is expanded to 40.
If it is already expanded, returns to the original status. At this time, all placement
data disappear except for no. 1 array PCB.
<Filter> Group
Designates the conditions for indicating the placement point shown in the Step dialog
box. Clicking the button will display the filtering function.
<Filter> combo box
Selects the conditions for indicating the placement point. Either ‘Feeder’ or ‘Part’
can be selected. Default is ‘Head’.
When Feeder is selected from the <Filter> combo box
Select the feeder for the part for which the placement point is to be indicated.
When Part is selected from the <Filter> combo box
Select the part for which the placement point is to be indicated.
When Ref is selected from the <Filter> combo box
Enter the reference of the part on which you want to mark the mounting point
in the edit box below.

9-7
Step Programming
<Filtering> button
Indicates only the placement point that is filtered according to the condition
selected from the <Filter> combo box in the “Steps” dialog box.
button
<None>
The panorama recognition function of the PCB vision is not used.
<Panorama>
It is possible to display the PCB shape on one vision window by performing split
recognition of the PCB shape and composing the split images into one.
<Insert 1Line> button
Adds a new placement point before the line (placement point) currently selected from
the <Grid>.
<2Pt. Teach> button
When a placement position is set, performs the function of teaching 2 corner points,
calculating the center point and using it as the placement point. Please refer to “8.1.1
Feeder Base”<2Pt. Teach…> button for more information.
<Fiducial…> button
If the placement point has a fiducial mark, sets the fiducial mark data. Closes the
dialog box without saving the changed contents.
None
Panorama

9-8
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
<Position Type> combo box
Select the number of fiducial marks. Available numbers of fiducial marks are as
follows.
None: No fiducial mark.
1 Part: 1 fiducial mark for placement point adjustment.
2 Part: 2 fiducial marks for placement point adjustment.
Please refer to “6.3. Fiducial Mark Setup” for more information.
<Offset…> button
Adds the offset value to the position of placement point. Before executing this
function, X column or Y column or Z column or R column or the line to add the offset
value must be selected in the grid. When this button is clicked on, the following dialog
box is displayed.
<When one of X, Y, Z, and R is selected>
Apply the offset value to the selected part.