DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第525页
15-59 System Setup <Use RESCUING> chec k box When this check box is ticked, the <Enabl e RESCUING> check box is activated in the <Operation Option> area of the “Product” menu . For details on this fun…

15-58
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
Used to back up the MMI file manually when the user shuts the machine down. The
user can back up the MMI file manually only when the machine is in the idling state.
Figure15.19“Error Report” dialog box
<Use> check box
Checking this check box will allow the file backup function to be used.
<Path> edit box
Sets the path for MMI file backup.
<Ignore Restriction Pitch> check box
Ticking this check box will override any constraints on the Feeder Pitch settings of a
part.
When setting the Feeder Pitch of a part, the following restrictions are set by default.
Parts of 1005 or less (the Y size of a part is less than 0.65mm)
Feeder Pitch: Only 2mm or less can be selected
When an unavailable Pitch is selected, the following warning window appears.
Parts of 1608 or more (the Y size of a part is more than 0.65mm)
Feeder Pitch: Only 4mm or less can be selected
When an unavailable Pitch is selected, the following warning window appears.

15-59
System Setup
<Use RESCUING> check box
When this check box is ticked, the <Enable RESCUING> check box is activated in the
<Operation Option> area of the “Product” menu. For details on this function, refer to
“13.1.2. Option Setting”.
<Light Sync for Part(Only Fly Cam)> check box
This is used when it is necessary to collectively change the lighting value of parts that
use the fly camera. When this check box is ticked, the <Change Fly Light> button is
activated in the “Parts” window.
<PNP Connection Check> check box
Checks whether the machine and PNP are connected before starting production.
Starting production with the machine not connected to the PNP will display an error
message.
<Use Pickup Offset Sync> check box

15-60
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
This is selected when applying the feed angle (R) and mounting angle (Part R) of the
stick or tray feeder to the parts data registered in the feeder. When this check box is
ticked, each time the PCB file is opened, the feed angle and mounting angle of the part
are changed to the feeder data.
<Auto Apply Pick Up Height> combo box
When this check box is ticked, the pickup height of the part is automatically reflected
to the feeder Z value, but only for feeders whose reel type is Paper. (Pickup height of
the part: Thickness of the part - 0.1mm)
When changing the model, it takes a long time to set the pickup height of the part
when the number of tape feeders is large. At this time, you can shorten the model
change time by using this function.
[e.g.: Chip parts with a thickness of 0.450]
[Auto Apply Pick Up Height = Use]
[Auto Apply Pick Up Height = Not Use]
<Apply Prev Slot Data(Only Tape Feeder> check box
When producing two models (A, B) with the same placement of tape feeders using
similar components, this function is used to apply the feeder information (X, Y, Z, R,
etc.) of an already taught Model A to the feeder information of Model B.
By using this function, no unnecessary teaching operation will be performed when
Model B is produced, and the preparation time can be shortened.
When this check box is ticked, the following dialogue box will be displayed when
opening the PCB file of Model B.