4-9 Tools Shortcut Menu Fiducial Mark’. Please refer to “7.1.1 Common Align Data” . Combo box Used for selecting the object to move to the designated coordinates by rotating the XY axis driving motor or to select the o…

4-8
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
4.3. ANC Setting
The ANC menu performs functions related to ANC setting including the arrangement of
nozzles on the ANC (Auto Nozzle Changer), nozzle pickups, and attachment. When this
menu is selected, the following dialog box is displayed.
Figure4.3 “ANC Setting…” dialog box
<Nozzle> combo box
Selects the nozzle to be arranged for the selected hole.
<Select> option button
Select the ANC number to set.
Warning When the nozzle is needed to arrange manually, Open the
ANC shutter using <Shutter Open/Close> button and after
pushing the <EMG> switch in the front operation panel or in
the rear operation panel, arrange the nozzle manually. And
release the <EMG> switch and push the <Reset> switch. If
this procedure is not followed, personal injury could occur.
Be sure to follow this procedure.
<Teach> group
Used for moving the selected object to the assigned position of coordinates by rotating
XY axis driving motor, or for obtaining the present coordinates of the fiducial camera.
<Light> button
Setup the illumination of fiducial camera to be used for teaching the ‘ANC

4-9
Tools Shortcut Menu
Fiducial Mark’. Please refer to “7.1.1 Common Align Data”.
Combo box
Used for selecting the object to move to the designated coordinates by rotating the
XY axis driving motor or to select the object for which the present coordinates is
searching. Selectable objects are as follows;
Fid Cam1/2: Select the fiducial camera.
Head 1 ~ Head 10: Select #1 ~ #10 heads.
<Move> button
Move the object selected in the combo box to the position of the assigned
coordinates. At this time, before executing <Move> button, the hole
corresponding to the desired position must be clicked on with a mouse.
<Get> button
Obtain coordinates for XY axis with reference to the object selected in the combo
box. At this time, before executing <Get> button, the hole corresponding to the
desired position must be clicked on with a mouse.
<Fiducial Mark Detail…> button
Set the ANC fiducial mark data. For more details. refer to Section “7.1.1 Common
Align Data”.
<Move Next Hole> button
Moves the device selected from the combo box in <Teach> group to the hole next to
the currently selected hole in the ANC.
<Shutter Open/Close> button
When this button is clicked on, the ANC shutter is Opened or Closed.
<Head-Inspect Nozzle Type> button
Clicking this button will perform the inspection of the type of the nozzle inserted in
the nozzle holder of the currently selected head. Since separate setup is needed to
enable this function, our C/S department must first be contacted.
The nozzles whose types can be checked are as follows:
CN030, CN040, CN065, CN140, CN220
<All-Inspect Nozzle Type> button
Clicking this button will inspect the types of nozzles inserted in the nozzle holders of
all heads. Since separate setup is needed to enable this function, our C/S department
must first be contacted.
The nozzles whose types can be checked are as follows:
CN030, CN040, CN065, CN140, CN220
<Pick & Put> group
<No real motion> check box

4-10
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
When this button is checked, manipulates the data for pick and put functions
without actual operation.
<Pick> button
When this button is clicked on, picks up the nozzle in the currently selected hole
of the ANC. Select the head to pick in the combo box in the <Teach> group.
<Put> button
When this button is clicked on, puts the nozzle in the head selected in the
“Device” to ANC.
<Put all nozzle> button
When this button is clicked on, puts the nozzles in all the heads to the ANC.
<View All Nozzles / Move Heads Safe> button
Used to move down the Z axis of all heads of the selected gantry of certain height so as
to check visually if any nozzle exists on the nozzle head.
After the visual check, if clicked again, Z axes of all heads are moved up to the
original position.
<Different ANC Info.In Current PCB file> list box
Shows the difference between the ANC setting of the currently loaded PCB file and
the ANC setting of the currently working equipment system. To change the system
setting to the PCB file setting, click on the <PCB->System> button on the right and
change the nozzles in other holes with different settings to fit the setting.
<PCB->System> button
Change the system setup to the PCB file setup
Warning When Manual ANC movement is executed, the nozzle of
the head and other areas of the machine might collide
unless the programmed nozzle and the actual nozzle
coincide. Be sure to match the programmed nozzle and the
actual nozzle in the machine.
<Close> button
Pressing this button will save the changed setup and close the current dialog box.