DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第222页
7-58 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide Fine The boundary of the corner is recogni zed precisely . It is recommended that this method be selected. Rough The value for the boundar…

7-57
Part Registration
<Corner Check> button
Even though the shape of the part is rectangular, it is curved differently compared to
the shape of general leads. Therefore, it is applied to a part that is difficult to register.
Clicking this button will display the following dialog box to set the corner type. Used
only for Trimmer parts
<Top Left set> check box
If the upper left corner of the part is a round shape with a bright colored pattern,
select this check box.
<Top Right set> check box
If the upper right corner of the part is a round shape with a bright colored pattern,
select this check box.
< Bottom Left set> check box
If the lower left corner of the part is a round shape with a bright colored pattern,
select this check box.
< Bottom Right set> check box
If the lower right corner of the part is a round shape with a bright colored pattern,
select this check box.
<Use Corner Check> check box
When using the <Use Corner Check> corner check algorithm, select this check
box.
<Corner Check Algorithm> check box
Select the vision algorithm to be used to perform the corner check.

7-58
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
Fine
The boundary of the corner is recognized precisely. It is recommended that
this method be selected.
Rough
The value for the boundary of the corner is not checked. It is not
recommended that this method be selected.
<Score> edit box
Enabled when the <Use Corner Check> is selected.
"Score” is the numerical value that indicates how accurately the recognized part
shape matches with the vision algorithm data selected from the <Corner Check
Algorithm> combo box when recognizing the part shape. This "Score” has a value
between 0 and 1000 points.
<Gap X/Y, Corner X/Y> edit box
The corner of the area to be recognized as X / Y direction size.
<Use flip check> Check box
Checks for part flip-over. For more details, please refer to "7.1.2.4. TR component
data setting". for more information.

7-59
Part Registration
7.1.3. IC component data setting
7.1.3.1. SOP/ SOJ/ SOP2/ SOJ2 component data setting
Set the align data for SOP/ SOJ/ SOP2/ SOJ2 components.
Figure7.18 “Package Group =SOP” dialog box
Figure7.19 “Package Group =SOJ” dialog box