7-69 Part Registration pixel.Each pixel has a unique value between 0 and 255 according to the seen degree of brightness. Here, ‘Threshold V alue’ indicates the border value deciding whether each pixel shou ld be recogniz…

100%1 / 632
7-68
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
recognized with the crosshair center. Then the crosshair center becomes the
center of the area in which the polygon part is to be searched.
<Direction Mark> button
Sets the part placement direction.
<Direction Mark Parameter> group
<Type> combo box
None: There is no Direction Mark.
Triangle: Selected when the direction mark is a triangle.
Rectangle: Selected when the direction mark is a rectangle.
Circle: Selected when the direction mark is a circle.
H MARK: Selected when the direction mark is “H” mark.
<Threshold> edit box
The image viewed through the SM Vision window is composed of each
7-69
Part Registration
pixel.Each pixel has a unique value between 0 and 255 according to the
seen degree of brightness. Here, ‘Threshold Value’ indicates the border
value deciding whether each pixel should be recognized in white or black.
That is, setup the limitation for deciding if the image pixel should be black
or white when checking a bad mark.
The value can be adjusted by entering a numerical value in the edit box.
Check the <Auto> check box to automatically set up the <Threshold>
value.
<Size X> edit box
Displays the area size in the X direction.
<Size Y> edit box
Displays the area size in the Y direction.
<Pos X> edit box
Displays the X coordinate of the area center..
<Pos Y> edit box
Displays the Y coordinate of the area center.
<Rotation> combo box
Selects the rotating angle of the direction mark. The rotation angle can be
selected according to the direction mark type as follows:
Triangle:
Circle: The angle cannot be selected.
H Mark:
<Polarity> combo box
Select the color of fiducial mark. Available colors are as follows.
- White: the mark looks lighter than the surroundings.
- Black: the mark looks darker than the surroundings.
<4 Way Search> check box
This function ensures that even when IC parts are supplied in an irregular
direction, they are mounted normally. When the <4 Way Search> check box is
selected, the head adsorbs a part, is rotated by 4 different angles (0/90/180/270
degrees), and then recognizes the direction mark of the part. At this time, the
recognized angle can be reflected to the mounting angle, and parts can be
mounted properly and according to the direction of each part.
The function can only be used for IC parts whose shape is circular but whose
7-70
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
internal pattern is QFP. (This function cannot be used for Ball type parts such
as BGA.)
<Outline> button
Shows the image seen through the Vision in real display to which threshold is
not applied, or in the image (Binary) to which threshold is applied as
recognized by MMI.
<OK> button
Saves the align data and closes the dialog box.
<Cancel> button
Closes the dialog box without saving the align data.
<Move> button
Used for parts recognition test by manually picking up parts. Please refer to “Common
Align Data” for more information.
<Test> button
Tests component recognition by using the set align data. Please refer to “Common
Align Data” for more information.
<Make Image> button
Displays the component shape recognized by the MMI through the SM Vision window
by assembling the split images after performing split recognition of the component.
<Image Capture> button
Helps to specify the optimum lighting value. The lighting is gradually changed
automatically and the images are saved. The user can check the best image and
identify the optimum lighting value. Please refer to “Common Align Data” for more
information.