DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第443页
14-61 Machine Calibration 4. Click the <Next> button. 5. The head moves to the designated posi tion on the ANC automatically . Then the machine creates pneumatic pressure an d performs calibration while moving the …

14-60
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
Since the position at which the Z offset is measured deviates from the calibration tool
position (center) by 3mm, if any foreign material on the calibration tool is present,
remove it.
3. In the <Grid> group, select the Z axis for which the calibration is to be performed and
click the <Detect Z Offset> button after selecting the <Automatic> check box.

14-61
Machine Calibration
4. Click the <Next> button.
5. The head moves to the designated position on the ANC automatically. Then the
machine creates pneumatic pressure and performs calibration while moving the
spindle down from Head 1 to Head 10 in order.
6. If the calibration is completed, the calibration result is reflected on the Z column of the
<Grid> group automatically.
Click the <Update> button to apply the calibration result to the machine.
Memo The reference values for the Z-offset are as follows.
Head 1~ Head 10: -1.5 ~ 1.5 mm
If the Z offset value exceeds this range, it means that the head has a
serious problem. Therefore, check for the home location, spindle,
LM, and verify if the motor operates normally.

14-62
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
The following is the procedure to perform the ‘R-Offset Calibration’.
1. Assign nozzle CNT0 to ANC Hole No.1.
2. In the <Grid> group, select the R-axis for which the calibration is to be performed and
click the <Nozzle Holder Check> button.
3. Then the message “First, We must Put all Nozzles from Heads manually. To Moving
Down Z Axis, Click [Next].” appears in the message window. Remove all nozzles
inserted in the nozzle-holder manually by clicking the <Next> button.
At this time, for the ANC, the virtual nozzle CNT0 is set for the No. 1 hole of the ANC
and it is regarded that the corresponding head picked the CNT0 nozzle.