14-56 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide

14-55
Machine Calibration
Click the <Next> button to move the fiducial camera to the fix camera hole
position.
4. Then the message “1. First, Select Move Camera and Adjust Light Level. 2. After
then, Select Fix Camera and Adjust Light Level. 3. To Calibrate, Click [Next].”
appears.
Select "Fid Cam1" in the <Target Camera> combo box and click the <Light ...>
button to adjust the brightness of the lighting so that the Fix Camera Hole shown
in the SM Vision window is clearly visible.
Then, select "Fix Cam1" in the <Target Camera> combo box, and follow the same
procedure as for the fiducial camera.
When you have finished adjusting the brightness of the lighting, click the <Next>
button.

14-56
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide

14-57
Machine Calibration
5. The calibration is performed automatically. If it is completed, the calibration result
is displayed as shown in the following figure. Click the <Update> button to apply
the new calibration value.
6. If the calibration procedure is completed properly, the result as shown in the
following figure is displayed and then the message, “Fid-Cam Offset
Calibration(Using Hole) is Finished.”.