DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第359页

13-7 Production Setup  Small PCB (substrate) that is set to ‘W or k’ among array PCBs that use no bad mark  Small PCB (substrate) to which ‘One-T ime- Skip’ function is applied in the ‘PCB Array’ dialog box i s already…

100%1 / 632
13-6
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
'Part Info.' Group
Double-click the part to modify the data.
<PCB D/L> button
Starts production after downloading the PCB.
<Teach> group
Selects a device and teaches the mounting point.
<Dump> button
Dumps a part during pickup.
<Apply Offset To All Array Steps> button
Apply the edited steps to all arrays.
<Sample Production(Next)> check box
Stops using the function from the next cycle.
<One Time Calibration> check box
Tick this check box to perform “Runtime Calibration” at the start of production.
The “Runtime Calibration” function is performed only once. To perform “Runtime
Calibration” again, press the “STOP” button, tick this check box and press the
“START” button again.
<LCR Check Reset> button
Selecting this button deletes the LCR Check data, which is mainly used to initialize
production data.
If LCR Check data is deleted, LCR Check is performed upon starting the next
production.
<One Time Skip> button
Skip only the new PCBs fed to the equipment temporarily without placing them. Since
separate setup is needed to enable this function, our C/S department must first be
contacted.
When using this function, the following pre-requisitions shall be satisfied:
13-7
Production Setup
Small PCB (substrate) that is set to ‘Work’ among array PCBs that use no bad mark
Small PCB (substrate) to which ‘One-Time-Skip’ function is applied in the ‘PCB
Array’ dialog box is already set up
PCB download completed.
When these pre-requisitions are met, the ‘One-Time-Skip’ function is applied after
auxiliary menu of ‘Start’ or ‘Cont.’ is selected, and the placement is performed.
Clicking the button will display the following dialog box.
<1. Array> group
Sets whether to perform placement on small PCBs in the array PCB.
<No> column
Refers to each small PCB in the array PCB. It is created as many as the
number of small PCBs.
<Skip> column
Allows the small PCB selected in this column to be skipped without being
placed during placement and sets the small PCB indicated in the <2.Array
Layout> group to ‘Skip’.
<One Time Skip> column
Of the small PCBs set to ‘Work’ in the array PCB, it allows only the new PCB
fed to the equipment to be skipped temporarily without being placed.
In order to use the ‘One-Time-Skip’ function, select the corresponding small
PCB and click the <One Time Skip> button in the ‘Product Monitor’ tab
dialog box.
<2. Array Layout> group
Selects the small PCBs in the array PCB using the mouse. It indicates whether
currently set placement work has been performed or not on the small PCBs.
13-8
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
<Selection> option box group
[‘Work’ –Work on the PCB; ‘Skip’ –Not to work on the PCB]
<Click> option box
If the small PCB displayed on the ‘PCB Array Layout’ dialog box is selected
using the mouse with this option box selected, the setup of the corresponding
small PCB is changed.
If the small PCB set to ‘Work’ is selected, ‘Work’ is changed to ‘Skip’. If the
small PCB set to ‘Skip’ is selected, ‘Skip’ is changed to ‘Work’.
<Drag-O.T Skip> option box
After this option box is selected if the small PCBs displayed on the ‘PCB
Array Layout’ dialog box are selected by dragging the mouse, the setup of the
selected small PCBs is changed to ‘Skip’. It is useful when selecting several
small PCBs at once.
<Drag-Work> option box
After this option box is selected if the small PCBs displayed on the ‘PCB
Array Layout’ dialog box are selected by dragging the mouse, the setup of the
selected small PCBs is changed to ‘Work’. It is useful when selecting several
small PCBs at once.
For the PCB to which ‘One-Time-Skip’ function is applied, a yellow rectangle is
indicated on the PCB in the ‘Product Monitor’ tab dialog box.
13.1.2. Option Setting
Carries out the function of setting the operation scope. When this button is clicked on, the