9-16 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide  When all th e unregistered part informa tion is registered, they are displayed as follows.  <Export…> button Converts the step data c…

100%1 / 632
9-15
Step Programming
When the <OK> button is clicked after selecting a component, the name of the
selected file is inputted in the <1.Part Name> edit box.
Select the <Package Group> corresponding to the selected component and
revise the component profile according to the selected component.
Click the <Register> button to register the component to the PCB Part List.
9-16
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
When all the unregistered part information is registered, they are displayed as
follows.
<Export…> button
Converts the step data created by this machine into other format (SSA Format) ASCII
File. When this button is clicked on, the following dialog box is displayed.
9-17
Step Programming
Select the format to be converted and press the <Export> button. The formats that can
be selected are as follows:
IMP Format: Converts the file to the file in IMP format.
SSA Format: Converts the file to the file in SSA format.
When the “Save” button is clicked on after the ASCII File name has been set, converts
the step data into SSA format and saves the data under the set file name.
<Cancel> button
Cancels the edited data.