DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第506页

15-40 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide 9. Check the <Imp ort All> check box in the <Select Camera> group and click the <Import> button. 10. Select the LM_MAP_FIX …

100%1 / 632
15-39
System Setup
7. Click the <(Y)> button to perform the test automatically.
8. If the dialog box saying that the light mapping test has been completed is displayed,
click the <OK> button. Then click the <Close> button to close the mapping test dialog
box.
15-40
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
9. Check the <Import All> check box in the <Select Camera> group and click the
<Import> button.
10. Select the LM_MAP_FIX in the <Open> dialog box and click the <Open> button.
15-41
System Setup
11. Once the file import is completed, check whether light mapping data values increase
gradually from Level 0 to Level 15. Then click the <Update> button.
Ref. The test result value must be within ±10 from the following reference
value.
Side Outer Inner
0121212
1252323
2393335
3514245
4625154
5736064
6867075
7967985
8 105 87 94
9 115 95 102
10 125 103 112
11 135 111 121
12 143 118 128
13 151 125 136
14 160 133 145
15 168 140 152