00195722-0102_UM_X-Serie_SR605_EN.pdf - 第129页
User Manual SIPLACE X-Series 3 Technical data for the machine From software version SR.605.xx 07/2008 EN Edition 3.5 Placement head 129 3.5.3 6-segment Collect&Place h ead for high-speed IC placement 3 Fig. 3.5 - 5 6…

3 Technical data for the machine User Manual SIPLACE X-Series
3.5 Placement head From software version SR.605.xx 07/2008 EN Edition
128
Nozzle types 9 xx 9 xx
X/Y accuracy
c
± 45 μm/3σ, ± 60 μm/4σ ± 41 μm/3σ, ± 55 μm/4σ
Angular accuracy ± 0.5°/3σ, ± 0.7°/4σ ± 0.5°/3σ, ± 0.7°/4σ
Component range 98% 98.5%
CO camera type 28 29
Illumination level 5 5
Possible illumination level
settings
256
5
256
5
a) Please note that the component range that can be placed is also affected by the pad geometry, the cus-
tomer-specific standards and the packaging tolerances.
b) With 0201 package
c) The accuracy value was measured using the vendor-neutral IPC standard.

User Manual SIPLACE X-Series 3 Technical data for the machine
From software version SR.605.xx 07/2008 EN Edition 3.5 Placement head
129
3.5.3 6-segment Collect&Place head for high-speed IC placement
3
Fig. 3.5 - 5 6-segment Collect&Place head - Function groups, part 1
(1) Vacuum generator
(2) Turning station, DP axis
(3) Star with 6 sleeves - star axis
(4) Forced air valve
(5) Silencer

3 Technical data for the machine User Manual SIPLACE X-Series
3.5 Placement head From software version SR.605.xx 07/2008 EN Edition
130
3
Fig. 3.5 - 6 6-segment Collect&Place head - Function groups, part 2
3
(1) Intermediate distributor board, beneath the cover
(2) Star drive - DR motor
(3) Z axis motor
(4) Valve adjustment drive
(5) C&P component camera, type 29, 27 x 27, digital