00195722-0102_UM_X-Serie_SR605_EN.pdf - 第443页
User Manual SIPLACE X-Series 6 Station extensions From software version SR.605.xx 07/2008 EN Edition 6.10 Siemens interface 443 6.10 Siemens interface Item no. 001 16808-xx SIPLACE interface HF/X/D3 The conveyor inte rfa…

6 Station extensions User Manual SIPLACE X-Series
6.9 PCB alignment From software version SR.605.xx 07/2008 EN Edition
442
that monitor this position with laser light barriers (X-series, HF-series, HS-60, S-27 HM). The "PCB
alignment" option ensures that the PCBs are stopped at the same position on all PCB conveyors.
The "PCB alignment" option is available for both single and dual conveyors.
6
Fig. 6.9 - 1 PCB alignment
(1) Lifting table
(2) PCB stop
The PCB is transported into the placement area until the laser light barrier triggers the stop signal
for the PCB conveyor. The lifting table with the PCB stops then moves up into a position in which
the PCB is not yet clamped and can still be moved by the conveyor belts. The two PCB stops are
level with the PCB, and the PCB supports (magnetic pins) are already in contact with the PCB.
The two conveyor belts move the PCB against the PCB stops and align them at the same time.
The lifting table then moves into its top end position, clamps the PCB and releases it from the PCB
stops so as not to affect the placement process. After the placement process, the lifting table and
PCB alignment are lowered and the PCB is moved on.
6

User Manual SIPLACE X-Series 6 Station extensions
From software version SR.605.xx 07/2008 EN Edition 6.10 Siemens interface
443
6.10 Siemens interface
Item no. 00116808-xx SIPLACE interface HF/X/D3
The conveyor interface on the placement machines from the X-series is configured to the SMEMA
standard. It is, however, still possible to use this interface in accordance with the Siemens stan-
dard. This is a significant benefit when an X-series machine is to be integrated into older SIPLACE
lines, in which case it would not be necessary to retrofit the older machines to conform to the
SMEMA standard.
Simply configure the conveyor interface of the X-series machines to the Siemens standard and
connect the machines using the associated interface cable.
More detailed information can be found in the Siemens conveyor interface retrofit instructions",
item no. 00194343-01.
6.11 Package for splice detection
Item no. 00119642-xx Splice detection, table controller HF/X/D3
Item no. 00116937-xx Splice detection, stations package HF/X/D3
Item no. 00141xxx-xx Splice sensors for S tape feeder modules
(see Section 3.10.7
, page 190 for item numbers)
Splice detection serves to recognize a batch change for components. The component tapes are
attached to the splicing point by a metal strip. The component tape runs over the splice sensor
which is installed on the feeder module and signalizes a tape change.
6
6.12 Long board
Item no. 00119672-xx Stopper, Long board option, SIPLACE HF/X/D3
Item no. 00119629-xx Conveyor widths 250/508 mm ("Wide board"), X-series/D3
The following PCB formats can be placed on X-series machines:
6
Single conveyor (standard width) 50 x 50 mm² to 450 x 460 mm²
Single conveyor: Wide board 50 x 50 mm² to 450 x 508 mm²
Dual conveyor (standard width) 50 x 50 mm² to 450 x 216 mm²
Dual conveyor: Wide board 50 x 50 mm² to 450 x 250 mm²

6 Station extensions User Manual SIPLACE X-Series
6.12 Long board From software version SR.605.xx 07/2008 EN Edition
444
6
6
We can supply the Long board option as a retrofit kit for placing PCBs that are over 450 mm long.
If the Long board option is installed, then the following PCB formats can be processed:
6
6
6
The retrofit kit consists of the following parts:
– Complete mechanism: stopper, sensors, cables and assembly parts
– Optional CD for enabling the function on the SIPLACE Pro computer
– Retrofit instructions
PLEASE NOTE 6
The Long board option must be ordered 2x for the dual conveyor.
More detailed information can be found in the Long board retrofit instructions,
item no. 00193888-01.
Dual conveyor in Single conveyor mode 50 x 50 mm² to 450 x 416 mm²
Dual conveyor in Single conveyor mode: Wide board 50 x 50 mm² to 450 x 450 mm²
Single conveyor: Long board (standard width) 50 x 80 mm² to 610 x 460 mm²
Single conveyor: Wide board, Long board 50 x 80 mm² to 610 x 508 mm²
Dual conveyor: Long board 50 x 80 mm² to 610 x 216 mm²
Dual conveyor: Wide board, Long board 50 x 80 mm² to 610 x 250 mm²
Dual conveyor in Single conveyor mode: Long board 50 x 80 mm² to 610 x 416 mm²
Dual conveyor in Single conveyor mode: Wide board, Long
board
50 x 80 mm² to 610 x 450 mm²