00195722-0102_UM_X-Serie_SR605_EN.pdf - 第340页
5 Tasks for the operating personnel User Manual SIPLACE X-Series 5.6 Setting up the feeder modules From software version SR.605.xx 07/200 8 EN Edition 340 → Close the pick-up windo w (item 3 in Fig. 5.6 - 2 ) by returnin…

User Manual SIPLACE X-Series 5 Tasks for the operating personnel
From software version SR.605.xx 07/2008 EN Edition 5.6 Setting up the feeder modules
339
The X feeder module is locked in position in the component table by a latch, and cannot be pulled
out. The procedure for removing feeder modules from the component table is as follows:
→ Press the removal handle (item 1 in Fig. 5.6 - 1
, page 338). The removal handle jumps
out and the status display goes out.
→ Wait approximately 1 second until the lock (item 4 in Fig. 5.6 - 1
, page 338) releases the
feeder module.
→ Use the removal handle to pull the feeder module out of the component table. If you wait
longer than 5 seconds, the feeder module will be locked once more. The status display
lights up red and the message "Handle --->>" appears on the LCD display (item 3 in Fig.
5.6 - 1
, page 338).
→ Engage the removal handle once more. If the X feeder module is contained in the current
set-up, the status display lights up green and the track number and increment are appear
on the LCD display once more.
→ Press the removal handle again (item 1 in Fig. 5.6 - 1
, page 338) and now pull the feeder
module out of the component table.
5
5
5.6.3 Using the X feeder module on the component trolley (X-series)
5.6.3.1 Check the X feeder module before using it
Check the following points before you use a feeder module on the component table:
→ The feeder module must be in perfect condition.
→ Tap the cover foil rocker (item 2 in Fig. 5.6 - 2
, page 340) lightly to make sure that it is not
jammed.
→ Check that the area around the pick-up window (item 3 in Fig. 5.6 - 2
, page 340) is free
from loose components.
PLEASE NOTE 5
Empty the component disposal compartment (item 5 in Fig.5.6 - 2
, page 340) before you
shake components out of the feeder module.
→ Push the lever (item 4 in Fig. 5.6 - 2
, page 340) forward slightly to open the pick-up win-
dow (item 3 in Fig. 5.6 - 2
, page 340). This will raise the pick-up window slightly.
PLEASE NOTE 5
Do not press the lever if a component tape is inserted. The tensioned cover foil would move
the component tape on and expose the components.
→ Remove any loose components from beneath the pick-up window.

5 Tasks for the operating personnel User Manual SIPLACE X-Series
5.6 Setting up the feeder modules From software version SR.605.xx 07/2008 EN Edition
340
→ Close the pick-up window (item 3 in Fig. 5.6 - 2) by returning the lever (item 4 in
Fig. 5.6 - 2
) to its original position.
→ Remove loose components from the component table with a brush or use a vacuum
cleaner with appropriate nozzle.
PLEASE NOTE 5
If the component tape is already inserted, cut it off flush with the front edge of the feeder mod-
ule.
→ If the removal handle (item 1) is still protruding, then latch it in place.
5
Fig. 5.6 - 2 Check the X feeder module before using it
(1) Removal handle
(2) Cover foil rocker
(3) Pick-up window
(4) Lever for raising and latching the pick-up window
(5) Component disposal compartment

User Manual SIPLACE X-Series 5 Tasks for the operating personnel
From software version SR.605.xx 07/2008 EN Edition 5.6 Setting up the feeder modules
341
5.6.3.2 Inserting the X feeder module into the component table
5
Fig. 5.6 - 3 Inserting the X feeder module into the component table
(1) Front slider guide for the X feeder module
(2) Back slider guide for the X feeder module
(3) "Back" centering pin on the X feeder module
(4) "Front" centering pin on the X feeder module
(5) Recesses in the centering bar for holding the "back" centering pin
(6) Centering holes on the component table for holding the "front" centering pin
(7) Locking latches
(8) Guide profile for the component table (Ω profile)
(9) Insertion aid for the feeder module
5
→ Place the front slider guide (item 1 in Fig. 5.6 - 3) of the feeder module on the insertion aid
(item 9 in Fig. 5.6 - 3
) of the component table.
→ Hold the feeder module vertically and push it forward, along the guide profile (item 8 in Fig.
5.6 - 3
). The front (item 1 in Fig. 5.6 - 3) and rear (item 2 in Fig. 5.6 - 3) slider guides of the
feeder module slide on the guide profile (item 8 in Fig. 5.6 - 3
).
→ Carefully push the feeder module further until the "front" centering pin (item 4 in Fig. 5.6 - 3
,
page 341
) is pushed into the centering hole (item 6 in Fig. 5.6 - 3, page 341).