00195722-0102_UM_X-Serie_SR605_EN.pdf - 第372页

6 Station extensions User Manual SIPLACE X-Series 6.1 Nozzle changer From software version SR.605.xx 07/2008 EN Edition 372 6.1.1.4 Position of the nozzle changers for t he C&P20A head on the X3 machine 1 or 2 nozzle…

100%1 / 494
User Manual SIPLACE X-Series 6 Station extensions
From software version SR.605.xx 07/2008 EN Edition 6.1 Nozzle changer
371
6.1.1.3 Position of the nozzle changers for the C&P20A head on the X4 machine
1 or 2 nozzle changers may be installed at locations 1, 2, 3, and 4 for the 20-segment Col-
lect&Place head (items 1 and 2 in Fig. 6.1 - 2
). This gives a total capacity of 8 nozzle changers
with 48 magazines and a total of 576 nozzle holders.
6
Fig. 6.1 - 2 Position of the nozzle changer for the 20-segment Collect&Place head on the X4 machine
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles
(5) Nozzle magazine
6 Station extensions User Manual SIPLACE X-Series
6.1 Nozzle changer From software version SR.605.xx 07/2008 EN Edition
372
6.1.1.4 Position of the nozzle changers for the C&P20A head on the X3 machine
1 or 2 nozzle changers may be installed at locations 1, 3, and 4 for the 20-segment Collect&Place
head (items 1 and 2 in Fig. 6.1 - 3
). One nozzle changer may be installed at location 2. This gives
a total capacity of 7 nozzle changers with 42 magazines and a total of 504 nozzle holders.
6
Fig. 6.1 - 3 Position of the nozzle changer for the 20-segment Collect&Place head on the X3 machine
6
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles
(5) Nozzle magazine
User Manual SIPLACE X-Series 6 Station extensions
From software version SR.605.xx 07/2008 EN Edition 6.1 Nozzle changer
373
6.1.1.5 Position of the nozzle changers for the C&P20A head on the X2 machine
1 or 2 nozzle changers may be installed at locations 1 and 3 for the 20-segment Collect&Place
head (items 1 and 2 in Fig. 6.1 - 4
). A nozzle changer may be installed at locations 2 and 4. This
gives a total capacity of 6 nozzle changers with 36 magazines and a total of 432 nozzle holders.
6
Fig. 6.1 - 4 Position of the nozzle changer for the 20-segment Collect&Place head on the X2 machine
6
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles