00195722-0102_UM_X-Serie_SR605_EN.pdf - 第418页

6 Station extensions User Manual SIPLACE X-Series 6.3 Matrix tray changer From software version SR.605.xx 07/2008 EN Edition 418 – The standard nozzle ch anger for the T winHead cannot be used with a combination of T win…

100%1 / 494
User Manual SIPLACE X-Series 6 Station extensions
From software version SR.605.xx 07/2008 EN Edition 6.3 Matrix tray changer
417
6.3.3.2 Electrical ratings
6
6.3.3.3 Noise emissions
6
6.3.3.4 Permitted environmental factors
6
6.3.4 Installation notes for the MTC
An MTC may be docked at locations 2 and 4 on all the X-series machines in place of the compo-
nent trolley. To do this, the docking unit installed for the component trolley must be replaced with
the docking unit for the MTC. If you use the MTC at another location, the location that becomes
free may be set up with a component trolley once more.
NOTES 6
For the X2/X3/X4 machines:
The 20-segment Collect&Place head cannot be used in the vicinity of locations at which an
MTC is docked.
For the X3 and X4 machines:
Supply voltage 3 x 200 VAC ± 5 %; 50/60 Hz (Japanese version)
3 x 208 VAC ± 5%; 50/60 Hz (U.S.A. version)
3 x 400 VAC ± 5%; 50/60 Hz (European version)
Total power 1.5 kW
Rated current 2.7 A at 3 x 400 VAC
4.2 A at 3 x 208 VAC
Fuses 3 x 16 A
Rated power consumption of the largest
consumer
2 A
Max. noise emissions 74 dB (A)
Room temperature Between 15°C and 35°C
Atmospheric humidity
30 - 75 %
(No higher than 45% on average to prevent any pos-
sibility of condensation on the machine)
6 Station extensions User Manual SIPLACE X-Series
6.3 Matrix tray changer From software version SR.605.xx 07/2008 EN Edition
418
The standard nozzle changer for the TwinHead cannot be used with a combination of Twin-
Head and MTC in placement areas with two gantries. For this situation, there is a nozzle
changer in the placement area with two gantries (see Section 6.1.4.7
, page 402).
For the X2 machines:
It is not possible to install an MTC and productivity lift at the same time at location 4.
No nozzle changer can be installed at location 4 in conjunction with the MTC.
User Manual SIPLACE X-Series 6 Station extensions
From software version SR.605.xx 07/2008 EN Edition 6.3 Matrix tray changer
419
6.3.4.1 Dimensions
6