00195722-0102_UM_X-Serie_SR605_EN.pdf - 第94页

2 Operational safety User Manual SIPLACE X-Series 2.9 Energy state of the machine after switching off at the main po wer switch From software ver sion SR.605.xx 07/2008 EN Edition 94 2 Fig. 2.9 - 3 Power supply unit, bac…

100%1 / 494
User Manual SIPLACE X-Series 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.9 Energy state of the machine after switching off at the main power switch
93
2
Fig. 2.9 - 2 Power supply unit, front view
Q1 Main power switch
X102 Service socket
F1 Fuse for the service socket
2 Operational safety User Manual SIPLACE X-Series
2.9 Energy state of the machine after switching off at the main power switch From software version SR.605.xx 07/2008 EN Edition
94
2
Fig. 2.9 - 3 Power supply unit, back view
X100 Cable connection terminal for the power supply cable
L20 Discharge reactor with fuses F21, F22 and F23
Z1 Line filter
User Manual SIPLACE X-Series 2 Operational safety
From software version SR.605.xx 07/2008 EN Edition 2.9 Energy state of the machine after switching off at the main power switch
95
The following table specifies the voltages of modules when the automatic placement system is
switched off at the main switch, but still connected to the mains supply.
2
2.9.2 Placement system switched off at the main power switch and disconnected
The automatic placement system is unpowered, apart from slight residual voltages in the power
supply unit.
Module Voltage
Terminal panel X100
Line filter Z1
Terminals L1, L2, L3
3 x 200 VAC
3 x 208 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
Service socket X102
115 VAC
120 VAC
130 VAC
220 VAC
230 VAC
240 VAC
Automatic circuit breaker F1
115 VAC
120 VAC
130 VAC
220 VAC
230 VAC
240 VAC
Main switch Q1
Terminals L1, L2, L3
3 x 200 VAC
3 x 208 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
Main switch Q1
Terminals T1, T2, T3
0 VAC
Power supply unit
(see item 5 in Fig. 2.7 - 2
, page 88)
Test socket X11
GND X12
Test socket X13_1
Test socket X13_4
GND X13_7
< 10 VDC
< 10 VDC
< 10 VDC