00195722-0102_UM_X-Serie_SR605_EN.pdf - 第349页
User Manual SIPLACE X-Series 5 Tasks for the operating personnel From software version SR.605.xx 07/2008 EN Edition 5.6 Setting up the feeder modules 349 5.6.5.1 Prep aring the component t able (SIPLACE HF) and S feeder …

5 Tasks for the operating personnel User Manual SIPLACE X-Series
5.6 Setting up the feeder modules From software version SR.605.xx 07/2008 EN Edition
348
5.6.5 Using the S feeder module on the component trolley (HF-series)
5
Fig. 5.6 - 9 CO trolley (HF-series) with 15 locations for S feeder modules
(1) S feeder module
(2) Centering pin
(3) Centering ball
(4) Component table
(5) Connecting cable for the S feeder module

User Manual SIPLACE X-Series 5 Tasks for the operating personnel
From software version SR.605.xx 07/2008 EN Edition 5.6 Setting up the feeder modules
349
5.6.5.1 Preparing the component table (SIPLACE HF) and S feeder modules for set-up
→ Clean the contact surface for the feeder module.
→ Clean the contact surface on the component table.
→ Remove loose components from the component table with a brush or use a vacuum cleaner
with appropriate nozzle.
CAUTION 5
Avoid removing components from the component table with your fingers. You may hurt your-
self with tiny splinters of metal.
5.6.5.2 Inserting the S feeder module
→ First place the front of the feeder module (item 1 in Fig. 5.6 - 9, page 348), i.e. the side with
the slotted foot, onto the component table (item 4 in Fig. 5.6 - 9
, page 348), so that the cen-
tering pin (item 2) on the component table slides into the slot in the feeder module foot.
→ Then lower the back of the feeder module until the centering ball (item 3 in Fig. 5.6 - 9
, page
348
) disappears completely into the hole in the feeder module.
→ Make sure that the feeder modules are placed correctly on the component table to suit their
width (see Fig. 5.6 - 10
, page 350).
→ Check that the feeder module is firmly seated on the component table. by tapping the side of
the feeder module with your finger. You should not be able to move it.
→ Connect the feeder module plug (item 5 in Fig. 5.6 - 9
, page 348) to the socket beneath the
location. The red dot on the plug must point towards the red dot on the socket.
PLEASE NOTE 5
When you connect the feeder module, make sure that you use the right socket for the location
since the feeder module receives the control pulse via this socket. The feeder module may
not work correctly if it is not connected to the right socket. The user manual for the feeder
modules used will contain detailed information on the assignment of plugs to sockets.

5 Tasks for the operating personnel User Manual SIPLACE X-Series
5.6 Setting up the feeder modules From software version SR.605.xx 07/2008 EN Edition
350
5
Fig. 5.6 - 10 Inserting 30 or 45 mm wide S feeder modules on the component table
(1) Feeder module, 30 mm wide
(2) Feeder module, 45 mm wide
(3) Centering ball
(4) Component table
5.6.6 Setting up the X feeder module
Setting up the X feeder modules is described in the job guide.