00195722-0102_UM_X-Serie_SR605_EN.pdf - 第283页
User Manual SIPLACE X-Series 4 Setting up and commissioning From software version SR.605.xx 07/2008 EN Edition 4.3 Setting up the placement machine 283 → Release the two horizont al tensioners (item 6 in Fig. 4.3 - 15 , …

4 Setting up and commissioning User Manual SIPLACE X-Series
4.3 Setting up the placement machine From software version SR.605.xx 07/2008 EN Edition
282
4.3.10 Fitting the extension kit on the PCB input side
4.3.10.1 Tools
– Allen keys, DIN 911, set
– Machine key
4.3.10.2 Assembly
4
Fig. 4.3 - 15 Fitting the extension kit on the PCB input side
(1) Extension kit
(2) Door
(3) Fillister head screw DIN 912, M6x16 and washer
(4) Ground connection point
(5) Conveyor cover
(6) Side panel, detached
(7) Drawer unit rail
(8) Box PC unit (see Section 4.3.11
, page 287)
(9) Axis unit (X3, X4: gantries 1 and 4)

User Manual SIPLACE X-Series 4 Setting up and commissioning
From software version SR.605.xx 07/2008 EN Edition 4.3 Setting up the placement machine
283
→ Release the two horizontal tensioners (item 6 in Fig. 4.3 - 15, page 282).
CAUTION 4
Do not unscrew the three bottom screws straight away. Simply loosen them so that the side
plate does not fall off.
→ Detach the ground cable from the side plate.
→ Remove both doors (item 2 in Fig. 4.3 - 15
, page 282) from the extension kit (item 1).
PLEASE NOTE: 4
To avoid damage, we recommend that a second person helps to assemble the extension kit.
→ Set down the box PC unit
a
(item 8 in Fig. 4.3 - 15, page 282) and the axis unit (item 9 in Fig.
4.3 - 15
, page 282) at the side of the machine in order to make enough space to fit the exten-
sion kit (item 1 in Fig. 4.3 - 15
, page 282).
→ Make sure that the connecting cables to the box PC unit and axis unit are not too tight.
→ Lift the extension kit (item 1 in Fig. 4.3 - 15
, page 282) against the machine frame and position
it so that the assembly bracket lies on the drawer unit rail (item 7 in Fig. 4.3 - 15
, page 282).
CAUTION 4
Make sure that the extension kit does not collide with the hexagonal shaft of the PCB con-
veyor and thus become bent.
→ Fix the extension kit using 4 fillister head screws M6x16 and the associated washers (item 3
in Fig. 4.3 - 15
, page 282).
a) see Section 4.3.11, page 287

4 Setting up and commissioning User Manual SIPLACE X-Series
4.3 Setting up the placement machine From software version SR.605.xx 07/2008 EN Edition
284
4.3.10.3 Fitting the guide for the hexagonal shaft
→ On the single conveyor, fix one guide for the hexagonal shaft (item 8 in Fig. 4.3 - 14, page
280
) to the extension kit using two fillister head screws M6x16 and washers.
→ On the double conveyor, fix two guides for the hexagonal shaft (item 8 in Fig. 4.3 - 14
, page
280
) to the extension kit using two fillister head screws M6x16 and washers.
4.3.10.4 Producing cable connections - extension kit on the PCB input side
4
Left-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/
cable
Start/stop button
Switch, PCB conveyor cover
X61/03020410 X61/03002537
Protective cover switch, location 4
X54/03020409 X54/03002540
Button for the component trolley docking unit, loca-
tion 4
X242/03021056 X242/03021054
Right-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/
cable
EMERGENCY STOP button
Start/stop button
X64/03020687 X64/03002538
Protective cover switch, location 1
X51/03020409 X51/03002539
Button for the component trolley docking unit,
location 1
X212/03021056 X212/03021051