Service Manual HS60.pdf - 第217页

Se rv ic e Ma nu al HS- 6 0 6 Mo du la r P C B c onve y or s y st em 03/ 2003 US Is sue 6. 14 Lig ht bar rier s and st oppe r fo r scan ning t he P CB pos i ti ons alon g the tran sport route s 215 6.14 Light barriers an…

100%1 / 348
6 Modular PCB conveyor system Service Manual HS-60
6.13 Width adjustment 03/2003 US Issue
214
Æ Undo and remove the screw fastening the actuator. (see also Fig. 6.13.28).
Æ Install the new actuator and screw in loosely.
Æ The switching point is set at the actuator on the conveyor side.
Move the adjustment unit to under the conveyor side.
Æ Place a gauge block of 2/10mm on the adjustment unit, press the actuator onto the gauge
block and tighten the screw.
Service Manual HS-60 6 Modular PCB conveyor system
03/2003 US Issue 6.14 Light barriers and stopper for scanning the PCB positions along the transport routes
215
6.14 Light barriers and stopper for scanning the PCB
positions along the transport routes
6.14.1 Function
The positions of the PCBs are scanned with the help of light barriers (transmitter and receiver
modules). The light barriers are installed above the conveyor belt and feel along the length of the
conveyor belt.
The light barrier signal stops the PCBs on the input conveyor, intermediate conveyor (HS-60 only)
and output conveyors. The light barrier in the placement area can be moved 50 mm against the
direction of transport to guarantee secure positioning of the PCB.
In the placement area the light barrier triggers the braking procedure via a DC motor. The soft-
ware regulates a constant time interval for the slow travel towards the laser light barrier.
6 Modular PCB conveyor system Service Manual HS-60
6.14 Light barriers and stopper for scanning the PCB positions along the transport routes 03/2003 US Issue
216
6.14.2 Replacing the light barriers for transmitter and receiver modules
(ab 00370063-01)
Fig. 6.14.29 Light barriers for transmitter and receiver modules (example shows S-27 HM)
Key
(1) Transmitter on input conveyor (4) Receiver on placement area
(2) Receiver on input conveyor (5) Transmitter on output conveyor
(3) Transmitter on placement area (6) Receiver on output conveyor