Service Manual HS60.pdf - 第80页
3 Pow er S up ply H S-6 0 S erv ic e Manu al 3. 7 M e as ur ing vol ta ge s on th e p o wer su pp ly unit 03/ 200 3 US I ssue 78 Modu le Designat ion T erminals V oltag es X1 Termina l panel Power s upply U, V, W 3 x 204…

HS-60 Service Manual 3 Power Supply
03/2003 US Issue 3.7 Measuring voltages on the power supply unit
77
3
Fig. 3.7 - 1 Measuring voltages on the front panel of the power supply unit

3 Power Supply HS-60 Service Manual
3.7 Measuring voltages on the power supply unit 03/2003 US Issue
78
Module Designation Terminals Voltages
X1
Terminal panel
Power supply
U, V, W
3 x 204 VAC / 3 x 230 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
BU1 Service socket 115 / 130 / 220 / 230 / 240 VAC
S1
Main switch
1, 3, 5 and
2, 4, 6
3 x 204 VAC / 3 x 230 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
MS1
Motor circuit-breaker
1, 3, 5 and
2, 4, 6
3 x 204 VAC / 3 x 230 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
SZ1
Main contactor
1, 3, 5 and
2, 4, 6
3 x 204 VAC / 3 x 230 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
SZ2
Contactor
1, 3, 5
2, 4, 6
3 x 140 VAC
3 x 140 VAC
SZ3
Contactor
1, 3, 5
2, 4, 6
3 x 140 VAC
3 x 140 VAC
SZ23
Contactor
1, 3, 5
2, 4, 6
3 x 140 VAC
3 x 140 VAC
SZ4 Contactor A1 (+) - A2 (-) 24 VDC
1, 2 24 VDC against ground
3, 4 24 VDC against ground
5, 6 24 VDC against ground
SSK
Combined contactor/
protective device L+, X3, X5 24 VDC against ground
F1 Fuse 1, 2 115 VAC / 130 VAC / 220 VAC
230 VAC / 240 VAC
against N on terminal panel X1
F3 Fuse 1, 3, 5 3 x 230 VAC
2, 4, 6
F4 Fuse 1, 3, 5 3 x 140 VAC
2, 4, 6
F5 Fuse 1, 2 100 VDC against negative pole of
rectifier V3 (see Fig. 3.7 - 2
on page 80)
F6 Fuse 1, 2 30 VDC against negative pole of rectifier
V4 (see Fig. 3.7 - 2
on page 80)
F7 Fuse 1, 2 40 VDC against negative pole of rectifier
V5 (see Fig. 3.7 - 2
on page 80)
F8 Fuse 1, 2 40 VDC against negative pole of rectifier
V5 (see Fig. 3.7 - 2
on page 80)
F9 Fuse 1, 2
10 VDC against negative pole of rectifier
V6
(see Fig. 3.7 - 2
on page 80)
F10 Fuse 1, 2 52 VDC against negative pole of rectifier
V7 (see Fig. 3.7 - 2
on page 80)
F11 Fuse 1, 2 30 VDC against negative pole of rectifier
V8 (see Fig. 3.7 - 2
on page 80)

HS-60 Service Manual 3 Power Supply
03/2003 US Issue 3.7 Measuring voltages on the power supply unit
79
3.7.5 Measuring voltages at rectifiers V1 to V8
The following diagram shows the position of rectifiers V1 to V8 and their terminal assignments. 3
To take measurements on rectifiers V1 and V7, you must first remove the perspex safety panel.3
RISK OF DEATH BY ELECTRIC SHOCK 3
Æ Switch the placement system off at the main switch.
Æ Disconnect the placement system from the power supply.
Æ Wait approximately 1 minute until the residual voltages have dropped to a safe level (electro-
lytic capacitor C1).
Æ Loosen the two M5 fillister head screws on rectifiers V1 and V7.
Æ Remove the perspex safety panel.
Æ Switch the placement system on and start it up.
Æ Measure the voltages.
3
PLEASE NOTE: The placement system must have started, otherwise there will be no AC volt-
age (3 x 140 VAC) at rectifier V1. V1 uses the 3 x 140 VAC to generate the 200 VDC supply volt-
age for the servo amplifiers of the gantry axes and 100 VDC for the servo amplifiers of the star
axes. These 100 VDC and 4 VDC supplies are fed to the AC voltage inputs of rectifier V2. Rectifier
V2 serves to "OR" the 4 VDC and 100 VDC supplies. If the placement system has not started, only
4 VDC will be present at the positive pole of rectifier V2. 3
3