Service Manual HS60.pdf - 第269页

HS -60 Se rvic e Ma nual 7 DLM2 Co l lect&Plac e Head 03/ 2003 US Is sue 7. 5 Rep laci ng th e coll ect &pla ce hea d / DLM2 (003 6777 0-0 1) 267 7.5. 4 Fittin g the collec t&place h ead on th e h ead m ount …

100%1 / 348
7 DLM2 Collect&Place Head HS-60 Service Manual
7.5 Replacing the collect&place head / DLM2 (00367770-01) 03/2003 US Issue
266
Æ Undo the four hexagon socket-head screws (M4x16) (item A in 7.5 - 3).
7
Fig. 7.5 - 3 Fixing the collect&place head on the head mount
Æ Carefully pull the collect&place head away from the parallel pins (Item 4 in Fig. 7.5 - 4) on the
head mount and remove it from the placement system.
HS-60 Service Manual 7 DLM2 Collect&Place Head
03/2003 US Issue 7.5 Replacing the collect&place head / DLM2 (00367770-01)
267
7.5.4 Fitting the collect&place head on the head mount
7
Fig. 7.5 - 4 Fitting the collect&place head
Æ Carefully move the collect&place head (item 1 in Fig. 7.5 - 4) onto the head mount (2).
Æ Make sure that the parallel pins (item 4 in Fig. 7.5 - 4) on the head mount slide into the holes
in the back part of the collect&place head.
Æ Carefully push the collect&place head towards the head mount until it is lying flat.
Æ Use four M4x16 hexagon socket-head screws to fix the collect&place head (A).
Æ Connect the plugs for the collect&place head to the head board.
The plug positions and assignment is shown in Fig. 7.5 - 1
.
CAUTION Check the polarity of the plugs before connecting. 7
7 DLM2 Collect&Place Head HS-60 Service Manual
7.5 Replacing the collect&place head / DLM2 (00367770-01) 03/2003 US Issue
268
Æ Make sure that the plugs are firmly locked in place.
Æ Check that the plugs of the 40-pin ribbon cables between the intermediate distribution board
and head board are correctly assigned:
Æ Make sure that the cables are not damaged and that there is no strain on the connecting ca-
bles.
Æ Connect the compressed air hoses.
7.5.5 Settings
Æ Close the protective cover.
Æ Check that you have removed all tools and equipment from inside the placement system.
Æ Start the placement system.
Æ Use the SITEST program to calibrate the collect&place head.
Cable Head board Intermediate distribution board
00333491-W1 X14 X1
00333491-W2 X13 X2
Tab. 7.5 - 2 Plug-in connections for the flat ribbon cables on the head board