Service Manual HS60.pdf - 第338页
8 Mo v ab le Com pon en t C h ange o ve r Ta bl e Serv i ce M an ua l H S- 60 8. 5 R es ol ving pr obl ems 03/ 2 003 U S I ssue 336 8.5. 4 Excha nging th e compone nt t able connection cable 8.5. 4.1 Power supply cable „…

Service Manual HS-60 8 Movable Component Changeover Table
03/2003 US Issue 8.5 Resolving problems
335
Fig. 8.5.2 Exchanging fixed castor(s) and/or guide castor(s)
Key for Fig. 8.5.2
1. Lay the component table on its side (2nd person required) before removing the rollers.
2. Fixed castors (2 units)
3. 8 Socket hex head cap screws M8 x 16
4. Guide castors (2 units)
5. 8 Socket hex head cap screws M8 x 16

8 Movable Component Changeover Table Service Manual HS-60
8.5 Resolving problems 03/2003 US Issue
336
8.5.4 Exchanging the component table connection cable
8.5.4.1 Power supply cable „component table“
Æ Perform the "Preparatory Steps" (see Section 8.5.1).
It is not necessary to dismantle the feeder modules.
Æ Unplug plugs X13 and X 15 of the communication unit cable.
Æ Disconnect the pneumatic hose.
Æ Disconnect the ground cable at the connection provided.
Æ The ground cable is looped through the component table and fastened at several connections.
To avoid weaving out the complete ground cable, disconnect the cable at the cable shoe.
Æ Open the cord grip and remove the entire cable.
Fig. 8.5.3 Component table cable
Æ Feed the new cable into the cord grip from the top to the bottom.
Æ Plug in the connection cable of the communications unit and reconnect the pneumatic system.
Æ Run the cable and attach cable ties.
Æ If you have no further parts to be exchanged, perform the appropriate "Final Steps",
including using SITEST to check the table function (see Section 8.5.7
).

Service Manual HS-60 8 Movable Component Changeover Table
03/2003 US Issue 8.5 Resolving problems
337
8.5.5 Exchanging the Communications Unit
Fig. 8.5.4 Exchanging communications unit; view in direction "component table termination panel"
Key for Fig. 8.5.4:
1. Communications unit
2. Fasteners for the communications unit: 4 M4 x 6 socket hex head cap screws
3. Cable "component table"
4. Ground cable with cable shoe
8
Æ Perform the "Preparatory Steps" (see Section 8.5.1).
It is not necessary to dismantle the feeder modules.
Æ Unplug the two plug-and-socket connections for the "component table“ cable, at the back of
the communication unit housing (3) and remove the ground cable (4).
Æ Hold the communication unit and undo the fastening screws (2).
Æ Remove the communication unit (1).