Service Manual HS60.pdf - 第263页

HS -60 Se rvic e Ma nual 7 DLM2 Co l lect&Plac e Head 03/200 3 US I ssue 7.4 Points to note before starti ng servicin g work ... 261 7.4 Point s to n ote befor e st arting servi cing wo rk ... Æ E nd all placement op…

100%1 / 348
7 DLM2 Collect&Place Head HS-60 Service Manual
7.3 Parts overview 03/2003 US Issue
260
7
Fig. 7.3 - 3 DLM2 collect&place head - parts overview 3
Item in Fig. 7.3 - 3 Designation Item no.
1 Star fitted / DLM2 00341181-01
2 "Z-axis down" sensor 00321524-05
3 RSF digital encoder 12/DLM2 00335990-02
HS-60 Service Manual 7 DLM2 Collect&Place Head
03/2003 US Issue 7.4 Points to note before starting servicing work ...
261
7.4 Points to note before starting servicing work ...
Æ End all placement operations on the placement system.
Æ Switch the placement system off at the main switch.
Æ Wait, until the operating system has shut down and the UPS has switched off.
Æ Disconnect the placement system from the power supply.
Æ Disconnect the placement system from the compressed air supply.
Æ Switch off the motor contactor in the power supply unit and secure the operating lever with a
padlock.
7
Fig. 7.4 - 1 Locking the motor contactor
(1) Turn the operating lever (1) counter-clockwise.
(2) Use the screwdriver to push the locking lug (2) out of the operating lever (1).
(3) Secure the operating lever with a padlock (3).
7 DLM2 Collect&Place Head HS-60 Service Manual
7.4 Points to note before starting servicing work ... 03/2003 US Issue
262
The Tag Out alternative:
If a machine can be locked out, it must be. However, there are situations where energy isolat-
ing devices can not accommodate locks. In these cases, the energy isolating devices must be
tagged to warn employees that the machine is de-energized for servicing. The tag must be se-
curely fastened, it must be placed in a position visible to all and it may only be removed by the
person who attached it. 7
WARNING
To avoid damaging the collect&place head, ALWAYS observe the following points when
moving the gantry: 7
NEVER move the gantry by pushing with your hands against the collect&place head.
NEVER push the gantry while the Z-axis is lowered.
Take hold of the cast iron part of the X-axis - ideally near the X-axis toothed belt deflection
pulley - and then move the gantry.