Service Manual HS-60 2 Operational safety
03/2003 US Issue 2.6 Disabling the compressed air supply and discharging the pressure
55
2.5.2 Residual voltages and discharge times after switching off at the main switch
CAUTION To avoid losing data, evaluate the following criteria before switching off
your automatic placement system (apart from in emergencies): 2
– Has the placement system finished transmitting machine, setup and panel data?
– Has the placement system finished processing the PCB?
– Has the placement system completed the run-up phase?
2.6 Disabling the compressed air supply and discharg-
ing the pressure
The compressed air working pressure is set to 0.55 MPa (5.5 bar). The position of the compressed
air unit is indicated by item 4 in Fig. 2.6 - 1
. The compressed air supply to the machine can be
interrupted using the shutoff valve (item 1 in Fig. 2.6 - 1
). 2
Æ Open the protective door.
Æ Turn the lever on the shutoff valve (item 1 in Fig. 2.6 - 1) from the vertical to the horizontal po-
sition.
Æ Watch the working pressure gauge and the pressure gauge for the compressed air supply to
the stopper (items 2 and 3 in Fig. 2.6 - 1
). When the automatic placement system is switched
on, the pressure discharges to 0 MPa (0 bar) within 1 minute.
CAUTION
When the machine is switched on, do not use the stop valve to interrupt the compressed air sup-
ply for more than 30 minutes. If you need to shut off the pneumatic system for longer in order to
carry out maintenance or servicing work, you must switch the placement system off at the main
switch and disconnect it from the power supply.
Test sockets X2, X3, X4
measured to X1 (GND)
Residual voltages when main
power switch is off Discharge times
X2 < 10 VDC < 2 sec.
X3 < 10 VDC < 50 sec.
X4 < 10 VDC < 7 sec.
2 Operational safety Service Manual HS-60
2.6 Disabling the compressed air supply and discharging the pressure 03/2003 US Issue
56
Fig. 2.6 - 1 Compressed air unit on the automatic placement system
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 2
(1) Shutoff valve lever in the CLOSED position
(2) Working pressure gauge
(3) Pressure gauge for the component table operating pressure
(4) Input pressure gauge
(5) Position of the compressed air unit on the placement system behind the safety door
Service Manual HS-60 2 Operational safety
03/2003 US Issue 2.7 Energy state of the machine after switching off at the main power switch
57
2.7 Energy state of the machine after switching off at
the main power switch
WARNING 2
The placement system is supplied with 3 x 204 VAC (US version), 3 x 230 VAC, 3 x 380 VAC,
3 x 400 VAC or 3 x 415 VAC ± 5 %, 50/60 Hz main power voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power
switch.Death, serious injury or considerable damage may result if this automatic placement sys-
tem is handled incorrectly.
Æ Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1).
Æ The guard over the servo unit must ONLY be opened by appropriately qualified and trained
personnel.