Service Manual HS60.pdf - 第327页

Se rv ic e Ma nu al HS- 6 0 8 M o va bl e C ompo ne nt C han ge ov er Ta ble 03/ 2 003 U S Iss ue 8.1 S afety Inst ruct ion s 325 8 Movable Component Change o ver Ta b l e 8.1 Safety Ins tr uction s DANGER The chap ters …

100%1 / 348
7 DLM2 Collect&Place Head HS-60 Service Manual
7.20 Replacing the complete Z-axis (03001959-01) 03/2003 US Issue
324
7
Service Manual HS-60 8 Movable Component Changeover Table
03/2003 US Issue 8.1 Safety Instructions
325
8 Movable Component Changeover
Table
8.1 Safety Instructions
DANGER
The chapters „Operational Safety“ and „Component Changeover Tables“ in the SIPLACE HS-60
user manual and the chapter „Operational Safety“ in this service manual take precedence.
These SIPLACE machines are powered by 120V / 208V +/- 5% (US version) or 3 x 230V/400V
+/-5% 50/ 60 Hz line voltage.
Parts of the system therefore carry dangerously high voltages! In specific modules the voltage is
present inside the machine base even when the main switch is turned off.
Handling the machines improperly or touching parts thereof which conduct high voltage may result
in death or serious physical injury as well as extensive property damage.
Observe the applicable accident prevention regulations, DIN standards and special safety codes
of your country at all times. DIN EN 60204 must be adhered to during all work inside the machine
base
The Siemens service engineer is the only person permitted to adjust / change the voltage, on the
basis of internal Siemens retrofitting instructions.
Furthermore, only the Siemens service engineer is permitted to adjust the height of the compo-
nent changeover table, on the basis of internal Siemens retrofitting instructions.
While working with the SITEST program, comply with the instructions in the DANGER text in Sec-
tion 8.5.7 „Final Steps“. 8
8 Movable Component Changeover Table Service Manual HS-60
8.1 Safety Instructions 03/2003 US Issue
326
DANGER: RISK OF PLACEMENT HEAD CRASH
With all SIPLACE machines, the Y- gantry must always be moved / pushed out of the area
of the component changeover table before changing tables.
This must be accomplished before actuating the compressed air switch to raise the table.
Otherwise there is a risk that the placement head may crash!! 8
WARNING
Parts of your body may be pinched, crushed or severed by the component changeover table if:
- the height is incorrectly set (SMEMA height may only be set by Siemens service engineer:
see Siemens in-house "Retrofit Instructions"),
- a feeder module tips over or falls,
- the component changeover table which has been moved out of the machine tips over
In addition, please comply with the special safety instructions in the relevant section below. 8
CAUTION
Improper actions while lowering or raising the handle of the component changeover table may
lead to a risk of minor injury through being pinched or scraped by the handle.
For this reason, always hold the handle with both hands. 8